Siemens SIMATIC NET RUGGEDCOM RX1536 Equipment Manual page 54

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1536:
Table of Contents

Advertisement

Military Standard Tests
MIL-STD-810G
RUGGEDCOM RX1536
Equipment Manual, 10/2023, C79000-G8976-1488-07
Test
IEC 60068-2-14
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60529
Test
6.2 EMC and Environmental Type Tests
Description
Change of Temperature
Vibration
Shock
Bump
Seismic
Ingress Protection
Description
Altitude
Certification
Test Levels
5 cycles at -40 to 85 °C
(-40 to 185 °F) and 3
hour dwells at rate of
1 °C/min (1.8 °F/min)
2 g @ 10-150 Hz
30 g @ 11 ms
10 g @ 16 ms
Method A
IP4x
Test Levels
12192 m (40000 ft) @ 40 °C, 90
minutes
Severity
Levels
 
Class 2
Class 2
Class 1
Level 2
 
45