2
Figure 4.4
Contamination hazard – risk of equipment damage
Prevent the ingress of water, dirt, and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty.
Note
Power modules are hot swappable. When installing/removing a power module, it is
not necessary to turn off power to the redundant power module.
Removing a Power Module
To remove a power module, do the following:
Electrocution hazard – risk of serious personal injury or death
Make sure power to the module is turned off before servicing the power supply
terminal.
1.
2.
3.
4.
5.
RUGGEDCOM RX1536
Equipment Manual, 10/2023, C79000-G8976-1488-07
Slot PS2
NOTICE
DANGER
Turn off power to the module.
Loosen the screws that secure the module to the chassis until the module can be
removed.
1
2
3
Figure 4.5
Removing a Power Supply
Slide the module out of the chassis.
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
Install a new or blank module to prevent the ingress of dust and dirt.