Siemens SIMATIC NET RUGGEDCOM RX1536 Equipment Manual page 24

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1536:
Table of Contents

Advertisement

2.
3.
4.
RUGGEDCOM RX1536
Equipment Manual, 10/2023, C79000-G8976-1488-07
4
2
Not Connected
1
Removable Screw Terminal Block
2
Non-removable Screw Terminal Block
3
Positive/Live (+/L) Terminal
4
Ground Terminal
5
Negative/Neutral (-/N) Terminal
6
Figure 2.6
AC Terminal Block Wiring – Screw Terminal Block for HI Power Supplies
Note
For secure, reliable connections under severe shock or vibration, use M3.5 ring
lugs with a maximum outer diameter of 7 mm (0.28 in). Make sure no bare
metal is exposed beyond the safety cover.
Connect the positive wire from the power source to the positive/live (+/L)
terminal on the terminal block.
Connect the negative wire from the power source to the neutral/negative (-/N)
terminal on the terminal block.
For screw terminal blocks, install the safety cover.
1
5
1
6
Installing the Device
2.5.1 Connecting High AC/DC Power
4
3
5
6
15