Siemens SIMATIC NET RUGGEDCOM RX1536 Equipment Manual page 41

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1536:
Table of Contents

Advertisement

Modules
4.4 Installing/Removing Power Modules
Installing a Power Module
To install a power module, do the following:
1.
2.
3.
4.
5.
6.
32
If equipped, remove the existing module.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to "Connecting Power" (Page 13).
Insert the module into the empty slot.
1
2
3
Chassis
1
Power Module
2
Screws
3
Figure 4.6
Installing a Power Module
Hand-tighten the screws to secure the power module to the chassis.
Turn on power to the device and confirm the module is receiving and supplying
power. This is indicated by the LEDs on the module.
LED
O
I
State
Green
The module is supplying power
Green
The module is receiving power
Description
RUGGEDCOM RX1536
Equipment Manual, 10/2023, C79000-G8976-1488-07