- Lighting Instructions for Millivolt Valve with 7 Day Timer -

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing
A.
This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B.
BEFORE OPERATING smell around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1.
Stop! Read the safety information above on this label.
2.
This appliance is equipped with an on-demand pilot that
shuts off after 7 days.
3.
Set the thermostat to lowest setting.
4.
Turn off all electric power to the appliance.
5.
Locate valve under the burner assembly.
6.
If the control knob is not already in the off position, i.e.
the word "OFF" in the 9 o'clock position, then push in
the gas control knob slightly and turn  clockwise to
"OFF". NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do not use
force.
Gas Control knob
shown in "PILOT"
position
7.
Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information above this
label. If you do not smell gas, go to next step.
Now push in the control knob slightly and turn 
8.
counter-clockwise to the "PILOT" position.
1.
Set thermostat to lowest setting.
2.
Turn off all electric power to the fireplace if service is to
be performed.
FOR YOUR SAFETY READ BEFORE LIGHTING
property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
If you cannot reach your gas supplier, call the fire
department.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and replace any part of the
control system and any gas control which has been
under water.
D. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, do not try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
9.
Push in the control knob all the way and hold it. With
the other hand push in the red igniter button until you
hear a click. Now observe closely the pilot burner
located on the rear center-left hand side of the main
burner. If a flame has appeared then continue to
depress the control knob until a BEEP is heard. This
procedure may take up to TWO MINUTES.
10. If the pilot flame did not appear then continue to
depress the red igniter button every 5 seconds until a
flame is established. NOTE: If after 30 seconds a
flame has not yet been established then turn the
control knob back to the off position and repeat steps
7, 8, and 9.
11. Once the pilot has been established hold the control
knob in the depressed position for approximately 25
seconds before releasing. If the flame goes out then
repeat steps 9 and 10.
• If the knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn the
gas control to "OFF" and call your service technician.
12. Now turn the control knob to the "ON" position. The
burner will not light unless the wall switch thermostat
or remote control is turned "ON" or in the case of the
thermostat there is a call for heat.
13. Close the access door.
14. Turn on all electric power to the appliance.
15. Set thermostat to desired setting.
16. If the appliance will not operate, follow the instructions
"To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
3.
Open the control access door.
Push in the gas control knob slightly and turn 
4.
clockwise to the "OFF" position. Do not force.
5.
Close the control access door.