Marquis MQHBZDV3636 Instruction Manual

“zero clearance” direct vent gas fireplace
Table of Contents

Advertisement

S O L A C E / S K Y L I N E
Model Numbers MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T,MQHBZDV4736
Stock #'s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQRB4236LP
MQHBZDV4236LP, are Certified to: ANZI Z21.88b-2008, CSA2.33b-2008, CGA 2.17-M91
MQRB4236NT, MQRB4236LPT, MQHBZDV4736N, MQHBZDV4736LP, are Certified to
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
Direct Vent Gas Fireplace
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions are not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to this manual.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
If you can not reach your gas supplier, call the fire department.
For Propane Horizontal installations the venting must be a minimum of one foot vertical
off the flue before going horizontal.
A Division of R-Co. Inc. • 2340 Logan Avenue • Winnipeg, Manitoba, Canada R2R 2V3 • Ph: (204) 632-1962
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Listed Certified for USA. and Canada
ANSI Z21.50a-2008/CSA 2.22a-2008, CGA 2.17-M91
"Zero Clearance"
Read this complete manual before beginning installation.

FOR YOUR SAFETY

vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
Printed in Canada July 22, 2009 Part # 36MQ-MAN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MQHBZDV3636 and is the answer not in the manual?

Questions and answers

Summary of Contents for Marquis MQHBZDV3636

  • Page 1: For Your Safety

    INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Listed Certified for USA. and Canada Model Numbers MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T,MQHBZDV4736 Stock #’s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQRB4236LP MQHBZDV4236LP, are Certified to: ANZI Z21.88b-2008, CSA2.33b-2008, CGA 2.17-M91 MQRB4236NT, MQRB4236LPT, MQHBZDV4736N, MQHBZDV4736LP, are Certified to ANSI Z21.50a-2008/CSA 2.22a-2008, CGA 2.17-M91...
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Dimensions & Installation of Wall Mount Surrounds ....27 Fan Installation - MQHBZDV3636/4236/4736 ....28 Installing MQRB4236 Liner Panels .
  • Page 4: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 5: Installation And Operation

    Installation and Operation Installation Regulations 4. Under no circumstances should this appliance be modi- fied. Any parts that have to be removed for servicing This gas appliance must be installed by a qualified installer should be replaced prior to operating this appliance. in accordance with local building codes, or in the absence of 5.
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 7: Locating Your Appliance

    MQHBZDV3636 - Locating your Appliance Installing with Top Vent A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the hori- zontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 8: Framing Your Gas Fireplace

    MQHBZDV3636 - Framing for your Gas Fireplace Framing Specifications 4. When installing horizontal with a 90 degree bend maintain a mini- mum of two and a half (2.5”) inches above the bend in enclosures. 1. Cold climate installation recommendation: When installing this fire- 5.
  • Page 9: Framing & Facing Requirements

    MQHBZDV3636 - Framing and Facing Requirements HBZDV36 WITH HB36CVCK (CLEAN VIEW CIRCULATING KIT) HB36CVCK WITH MQHB36SW SURROUND...
  • Page 10: Installing Clean View Kit (Cvck)

    MQHBZDV3636 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly 1. Install optional Fan Kit (See Fan Instruction) 2. Fold two standoffs up into position & mount with supplied Screws. (Fig. 1) 3.
  • Page 11: Parts List

    Overlays MQHBZDV3636 Parts List HB36ADTH Arch Door Frame - Top Half Black Fireplace Part Numbers HB36ADDX Arch Door Frame - Deluxe Black MQHBZDV3636N Fireplace Heater Rated NG, Ceramic Glass, HB36ADDA Arch Door Frame - Double Arch Black 30,500 BTU AT 75% efficient. Approved for...
  • Page 12: Kingsman Fireplace Venting

    Kingsman Fireplace Venting Catalog Number Description Galvanized Pipe 7” Dia. x 48” (Vertical ZDVHSK Horizontal Vent Starter Kit - 3 FT Length ZDV48GP Installations) Horizontal Vent Termination, Wall Thimble, 36” Flex Pipe, Mill Pac, screws/washers, springs. ZDVAAF Flashing 7” c/w Storm Collar (1/12 to 7/12) ZDVHSK5 Horizontal Vent Starter Kit - 5 FT Length ZDVAF2...
  • Page 13: Locating You Appliance

    MQHBZDV4236/MQRB4236 - Locating your Appliance A - Flat on a wall D - As a room divider Installing with Top Vent B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 14: Framing Your Gas Fireplace

    MQHBZDV4236/MQRB4236 - Framing for your Gas Fireplace Framing Specifications 1. Cold climate installation recommendation: When installing this fire- 5. For a fireplace with louvers combustible floor can raise 1” place against non insulated exterior wall or chase, it is recom mended above the bottom of the fireplace.
  • Page 15: Framing & Facing Requirements

    MQHBZDV4236/MQRB4236 - Framing and Facing Requirements HBZDV42 WITH HB42CVCK (CLEAN VIEW CIRCULATING KIT) HB42CVCK WITH MQHB42SW SURROUND *Note: A HBCVCK must be used when installing a MQHBSW Wall Surround.
  • Page 16: Mqhbzdv4236/Mqrb4236

    MQHBZDV4236/MQRB4236 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly 1. Install optional Fan Kit (See Fan Instruction) 2. Fold two standoffs up into position & mount with supplied Screws. (Fig. 1) 3.
  • Page 17: Parts List

    Rock Set Multi-Color (HBZDV/MQRB) Refractory Liner MQRSP2 Rock Platform, Support and 4 Screws HB42PL Porcelain Reflective Liner (all HB42 models) (MQHBZDV3636, MQHBZDV4236) MQRB42PB Porcelain Bottom for MQRB4236 MQEMBER Glowing Embers, 2 ea. (MQRB4236)optional HB42RLC Refractory Liner Classic (all HB42 models) MQRBD1 Driftwood/Rocks, 4 ea.
  • Page 18: Kingsman Fireplace Venting

    Catalog Number Description Miscellaneous Parts 1000-150GE #Silicone GE Red IS806 #736 1000-150MP #Hi-Temp Mill Pac Sealant 840099 1000-214 #Piezo-Igniter 1244-17 MARK 21 1000-215 #Pal Nut (18MMXI.5MM)BLK (1364.03) 1000-218 #Switch Ivory (1451/001) 1000-227 #Cover Ivory (86001/001) 1000-255 #Orifice Brass - (State Size) 1000-EMBER #Moon Rock 2000-080...
  • Page 19: Locating You Appliance

    MQHBZDV4736 - Locating your Appliance A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner Installing with Top Vent C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 20: Framing Your Gas Fireplace

    MQHBZDV4736 - Framing for your Gas Fireplace Framing Specifications sures,insulation sleeve is required. If greater than six and a half (6.5”) an insulation sleeve is not required. 1. Cold climate installation recommendation: When installing this fire- place against non insulated exterior wall or chase, it is recom mended 5.
  • Page 21: Framing & Facing Requirements

    MQHBZDV4736 - Framing and Facing Requirements HBZDV47 WITH HB47CVCK (CLEAN VIEW CIRCULATING KIT) HB47CVCK WITH MQHB47SW SURROUND...
  • Page 22: Installing Clean View Kit (Cvck)

    MQHBZDV4736 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly 1. Install optional Fan Kit (See Fan Instruction) 2. Fold two standoffs up into position & mount with supplied Screws. (Fig. 1) 3.
  • Page 23: Parts List

    Child Safety Screens MQHBZDV4736 - Parts List HB47CSS Child Safety Screen - 47” DV Fireplaces HB47PSK Pull Screen for CVCK Fireplace Part Numbers Replacement Burner Assembly MQHBZDV4736N Fireplace Decorative Rated NG, Tempered Glass, 40,000 BTU 4736MQ-BNGSI BURNER ASSEMBLY - NATURAL GAS C/W VALVE SYSTEM (MQHBZDV4736N) MQHBZDV4736LP Fireplace Decorative Rated LP, Tempered Glass, 40,000 BTU...
  • Page 24: Kingsman Fireplace Venting

    Kingsman Fireplace Venting Catalog Number Description ZDV48GP Galvanized Pipe 7” Dia. x 48” (Vertical ZDVHSK Horizontal Vent Starter Kit - 3 FT Length Installations) Horizontal Vent Termination, Wall Thimble, 36” Flex Pipe, Mill Pac, screws/washers, springs. ZDVAAF Flashing 7” c/w Storm Collar (1/12 to 7/12) ZDVHSK5 Horizontal Vent Starter Kit - 5 FT Length ZDVAF2...
  • Page 25: Clearance, Mantels & Surrounds

    CLEARANCES - MQHB36/42/47/MQRB4236 - Mantels & Surrounds Warning: Combustible objects must not be placed on a non-combustible mantel unless the non-combustible mantel meets the minimum height and width require ments for a combustible mantel.
  • Page 26: Mantel Leg Clearances

    Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using MQHBSW.
  • Page 27: Dimensions & Installation Of Wall Mount Surrounds

    MQSW Wall Mount Surround Dimensions Concave Convex HB36 HB36 HB42 HB42 HB47 HB47 Installation of MQ Wall Mount Surrounds Remove the old CAP (Control Access Panel), and the Lower CVCK panel by unscrewing the two support screws and drilling out the two rivets. Remove the two upper CVCK mounting screws located at H2 as shown in the figure below.
  • Page 28: Fan Installation - Mqhbzdv3636/4236/4736

    Fan Installation for HBZDV 36/42/47 Fan Installation instructions for HBZDV36/42/47 3. Wire Junction Box to 120v and wall mounted variable speed con- trol. Install a duplex outlet to junction box and plug fan into out- with or without CVCK (Clean View Circulating Kit) let.
  • Page 29: Installing Mqrb4236 Liner Panels

    Installing MQRB4236 Liner Panels...
  • Page 30: Brick Installation - Mqhbzdv3636/4236/4736

    Brick. Side brick must be flush with side wall of Firebox. Rotate clip down over Brick Panel and tighten screw. NOTE: Side Brick for MQHBZDV3636 & MQHBZDV4236 Top of side brick has to be tilted forward and hooked over bottom front lip of Firebox first then rotated backward into position.
  • Page 31: Installation Of Hb Porcelain Liners

    Installation of HB Porcelain Liners - HB36PL/HB42PL/HB47PL 1. Remove Door from the fireplace by unlatching the 2 latches on top of unit. 2. Remove back Log Holder by removing 3 screws from face of Log Holder. The Log Holder will have to be re- installed after the placement of the Back Panel.
  • Page 32: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1.
  • Page 33: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, & Burner Control Recommended Maximum Lead Length (Double Wire) When Using Wall Switch or Thermostat Wire Size Max. Length 14 GA. 100 FT. 16 GA. 64 FT. 18 GA. 40 FT. 20 GA. 25 FT. 22 GA. 16 FT.
  • Page 34: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 35: Burner System Removal - Mqhbzdv3636/4236/4736

    Burner System Removal for MQHB36/42/47 Removing Burner System / Access Cover for MQHBZDV36/42/47 If fireplace has been installed with optional CVCK (Clean View Circulating Kit) to service fan system or burner system controls, the access cover and burner system pan will have to be removed. CAUTION: BEFORE STARTING REMOVAL OF PARTS TURN OFF GAS SUPPLY.
  • Page 36: Gas Conversion - Mqhbzdv3636/4236/4736 & Mqrb4236

    Gas Conversion - MQHB3636/4236/4736 WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 37: Installation Of Gas Conversion Kit

    Section B - Installation Instructions Gas Conversion Kit for Top Convertible Pilot - Series 091065X Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG Only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 38: Door And Glass Information

    Model Series MQHBZDV4736 use Low E Tempered Glass. Must be 5mm thick. Only Robax ceramic or coated Neaoceram glass may be used for replacement for model MQHBZDV3636, MQHBZDV4236 and MQRB4236. Must be minimum 5mm thick. To replace glass, clean all materials from door frame.
  • Page 39: Log Placement Guide

    LOG PLACEMENT - LOGF36 PARTS LIST STEP 1: Place log #1 onto rear log holder and center. STEP 3: Locate 2 holes on the bottom of logs #4 and #5. STEP 2: Place log #2 onto left side of log. Place log #3 onto Position them onto left and right log placement tabs.
  • Page 40 MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 PARTS LIST STEP 1: Remove the log holder mount, log supports, and the STEP 2: Attach the back rock support with the 4 screws as grate bar. shown. Replace/reinstall the 2 screws from the grate bar.
  • Page 41: Rock F2 Setup

    MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 STEP 5: Place rocks #1 onto the burner as shown. STEP 6: Place rocks #3 onto the burner as shown. STEP 7: Place rocks #4 onto the burner as shown. STEP 8: Place rocks #6 onto the burner as shown.
  • Page 42 MQROCK1/MQRSP1 Setup for Models MQHBZDV4736 PARTS LIST: Rock #1 - 5 pieces; Rock #3 - 6 pieces; Rock #4 - 10 pieces; Rock #6 - 9 pieces. STEP 2: Attach the back rock support using the existing screws STEP 1: Remove the back log holder, log supports, and the grate from the back log holder.
  • Page 43: Rock F1 Setup

    MQROCK1/MQRSP1 Setup for Models MQHBZDV4736 STEP 6: Place rocks #4 into position as shown. STEP 5: Place rocks #3 into position as shown. Do not place rocks directly onto the burner tubes. STEP 7: Place rocks #6 into position as shown. STEP 8: Place remaining rocks #4 and #6 into position as shown.
  • Page 44: Accessories For Mqrb3328/3632/4236

    Accessories for MQRB3328, MQRB3632, MQRB4236 The following options are available for the MQRB Series. Each option may be used independently or in combi- nation with any other. #1: Bag of Silica Sand - Supplied with unit #2 MQRBD1 Rock and Log Kit - 4 Rocks and 4 Drift Wood Logs #3 MQ Ember Kit - 2 Bags of Glowing Embers Option #1 -Sand-The MQRB Ribbon Burners are supplied...
  • Page 45: Vent Termination

    Vent Termination N - Clearance to perpendicular wall 24 inches (60 cm). Vent Terminal (Recommended to prevent re-circulation of exhaust products. Air Supply For additional requirements check local codes.) NOTE: Clearances are to the edge of terminal plate, add 6- Area Where Terminal Not Permitted.
  • Page 46: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system (Model DV-GS Series), Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 47: Venting Graph

    How To Use The Horizontal Vent Table Venting Routes And Components Since it is very important that the vent system maintain its bal- 1. Determine the height of the system and the number of bends ance between the combustion air intake and the flue gas required.
  • Page 48: Installation Of Side Wall Venting

    Installation Of Side Wall Venting 1. Establish the minimum distance from the bottom of fireplace to centre of vent. MQHBZDV3636 Cut a hole through the wall allowing for a 11” x 11” (inside diameter) in com- bustible walls for wall thimble or an 8” diameter hole in a non-combustible wall (See Figure 1-2-3).
  • Page 49: Vertical Venting

    Venting Straight Up Through Roof Roof Flashing Ensure that you have the proper roof flashing by checking your 1. An Attic Insulation Shield must be installed where the vent passes roof pitch using a level and two rulers, or by using a roof pitch from a lower living space into an attic space where the chimney is card.
  • Page 50: Limited Lifetime Warranty

    LIMITED LIFETIME WARRANTY This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed inside the continental United States, Alaska, Hawaii, and Canada. The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable installation and building codes and good trade practices.

This manual is also suitable for:

Mqrb4236Mqhbzdv4236Mqrb4236tMqhbzdv4736

Table of Contents