Marquis Solara MQZDV3318 Installation Instructions Manual

Zero clearance direct vent

Advertisement

Stock #'s: MQZDV3318N, MQZDV3318NE, MQZDV3318LP, MQZDV3318LPE,
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before
going horizontal.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Solara

Installation Instructions

Listed Certified for USA and Canada
Model Numbers MQZDV3318, MQZDV3622
"Zero Clearance" Direct Vent Gas Fireplace
MQZDV3622N, MQZDV3622NE, MQZDV3622LP, MQZDV3622LPE
Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
FOR YOUR SAFETY
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Printed in Canada
November 1, 2012
Part # 3318MQ-MAN

Advertisement

Table of Contents
loading

Summary of Contents for Marquis Solara MQZDV3318

  • Page 1: Installation Instructions

    Solara Installation Instructions Listed Certified for USA and Canada Model Numbers MQZDV3318, MQZDV3622 “Zero Clearance” Direct Vent Gas Fireplace Stock #’s: MQZDV3318N, MQZDV3318NE, MQZDV3318LP, MQZDV3318LPE, MQZDV3622N, MQZDV3622NE, MQZDV3622LP, MQZDV3622LPE Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91 This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    General Vent Installation Information..............Installation Of Side Wall Venting............... Venting Table....................Vertical Venting....................Vertical Venting over 15 Feet................MQZDV3318 Parts List..................MQZDV3622 Parts List..................Common Parts & Venting.................. 47 Glass Safety / Termination Cap Safety- All Units..........48 Limited Lifetime Warranty.................. 49...
  • Page 4: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Mqzdv3318 Locating Your Appliance

    MQZDV3318 - Locating your Appliance Installing with Top Vent A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizon- tal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 8: Framing For Your Gas Fireplace

    MQZDV3318 - Framing for your Gas Fireplace Framing Specifications 4. When installing horizontal with a 90 degree bend maintain a minimum of two and a half (2.5”) inches above the bend in 1. Cold climate installation recommendation: When installing this fire- enclosures.
  • Page 9: Framing And Facing Requirements

    Z33CVCK - Framing and Facing Requirements MQZDV3318 WITH Z33CVCK (CLEAN VIEW CIRCULATING KIT) Z33CVCK - with Wall Surround...
  • Page 10: Mqzdv3622 Locating Your Appliance

    MQZDV3622 - Locating your Appliance Installing with Top Vent A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizon- tal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 11: Framing For Your Gas Fireplace

    MQZDV3622 - Framing for your Gas Fireplace Framing Specifications 4. When installing horizontal with a 90 degree bend maintain a minimum of two and a half (2.5”) inches above the bend in enclosures. 1. Cold climate installation recommendation: When installing this fire- 5.
  • Page 12: Framing And Facing Requirements

    Z36CVCK - Framing and Facing Requirements MQZDV3622 WITH Z36CVCK (CLEAN VIEW CIRCULATING KIT) Z36CVCK - with Wall Surround...
  • Page 13: How To Install Clean View Kit (Cvck)

    How To Install Clean View Kit (CVCK) For ZDV3318 / ZDV3622 / ZDVRB3622 / ZDV6000 / ZDV3320 / MQRB3328 / MQZDV3318 / MQZDV3622 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 14: Clearances - Zdv3318/3622 - Mantels & Surrounds

    CLEARANCES - MQZDV3318/3622 - Mantels & Surrounds Warning: Combustible objects must not be placed on a non-combustible mantel unless the non-combustible mantel meets the minimum height and width require ments for a combustible mantel.
  • Page 15: Mantel Leg Clearances

    Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using MQHBSW.
  • Page 16: Clearance To Combustibles

    MQZDV3318 - Clearance to Combustibles Clearance to Combustibles Back (from Standoffs) 0 inches/0 mm Side (from standoffs) 0 inches/0 mm (NOTE -Floor) if installing the appliance directly on carpeting or Floor 0 inches/0 mm other combustible materials other Ceiling (from bottom of fireplace)
  • Page 17: Wall Mount Surrounds

    MQSW Wall Mount Surround Dimensions MQ33SWF MQ36SWF 35-5/16” 37-5/32” 45-13/16” 50-5/16” 28-3/8” 32-15/16” 17-13/16” 19-5/8” 8-3/4” 8-3/4” 8-3/4” 8-3/4” 8-3/4” 8-3/4” 1” 1” 1-3/16” 1-3/16” Installation of MQ Wall Mount Surrounds 1. Set Surround Lip on CVCK Ledge and ensure that it is securely in place. 2.
  • Page 18: Fan Kit Installation

    Fan Kit Installation Fan installation Instructions for ZDV6000/3320/3318/3318MQ Wire Junction Box and wall mounted variable speed control to with or without CVCK (Clean View Circulating Kit). 120v. Install a duplex outlet to junction box and plug fan into outlet. Note: Install Fan Kit Before Installing optional CVCK (Clean Turn the wall switch on (clockwise).
  • Page 19: Split Receptacle- Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 20: Z3318 / Z3622Prl & Z3318Ml / Z3622Ml Installation Guide

    Z3318 / Z3622PRL & Z3318ML / Z3622ML Installation Guide Make note of the position of the air adjustment plate before removing it. This position will have to be recalled when the air adjustment plate is reinstalled. Remove three [3] mounting screws from air adjustment plate and extract it from the firebox. (NOTE: The false bottom will have to be removed on models ZDV3318, ZDV3622 and ZDVRB3622.) Remove the [1] Liner Retaining Screw from each side of the firebox.
  • Page 21: 3318 / 3622 Door And Glass Information

    Steps 1 & 2. Use caution when removing broken glass, wear gloves. Removal of the Glass Door- ZDV3318 & MQZDV3318 : 1. Unlatch the two latches located behind the upper grill. 2. To remove, pull frame forward and lift from bottom 2 Hex Screws door retainer.
  • Page 22: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1.
  • Page 23: Burner System Removal

    Burner System Removal for MQZDV3318/3622 If fireplace has been installed with optional CVCK (Clean View Circulating Kit) to service fan system or burner system controls, the access cover and burner system pan will have to be removed. *CAUTION BEFORE STARTING REMOVAL OF PARTS TURN OFF GAS SUPPLY. DISCONNECT 110 VOLTS TO FAN SYS- TEM AND DISCONNECT 110 VOLTS TO ELECTRONIC IGNITION BURNER SYSTEM IF APPLICABLE WARNING: Electrical Grounding Instructions.
  • Page 24: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 25: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 26: Conversion Kit Instructions - Part A

    Conversion Kit Instructions – PART A Caution : The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction.
  • Page 27: Gas Conversion Kit For Top Convertible Pilot Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 28: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 29: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 30 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 31 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 32 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 33 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 34: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 35: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 36: Mqlogc22 Log Assembly

    MQLOGC22 for MQZDV3318/3622 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. NOTE: Log 1 is a two piece assembly.
  • Page 37 MQLOGC22 for MQZDV3318/3622 STEP 3: Align the hole on the bottom of log #3 with the log STEP 4: Place Log #4 into place as shown. Do Not place #3 placement tab and the rest log #3 on log #2 as shown.
  • Page 38: Mqrsp5

    MQRSP5 for MQZDV3318/3622 MQRSP5 Parts List Step 1: Remove the grate bar by removing the 2 Screws located on the left and right side of the grate bar as illustrated. Remove the 2 ember plates once the grate bar is removed. The...
  • Page 39 MQRSP5 for MQZDV3318/3622 Step 6: Place rocks #6 into place as shown. Do not place Step 7: Place rocks #4 into position as shown. Place the directly over the multiple porting areas. highlighted rocks into position being sure that they are crossing over the single line porting.
  • Page 40: Vent Termination

    Vent Termination WARNING: WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD (SAFETY CAGE) SHALL Measure to the edge of the termination plate. BE INSTALLED. Measure to the edge of the round termination. N - Clearance to perpendicular wall 24 inches (60 cm). Vent Terminal (Recommended to prevent re-circulation of exhaust products.
  • Page 41: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system (Model DV-GS Series), Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 42: Venting Table

    Venting Routes And Components How To Use The Horizontal Vent Table Since it is very important that the vent system maintain its bal- 1. Determine the height of the system and the number of bends ance between the combustion air intake and the flue gas required.
  • Page 43: Vertical Venting

    Venting Straight Up Through Roof Roof Flashing Ensure that you have the proper roof flashing by checking your 1. An Attic Insulation Shield must be installed where the vent passes roof pitch using a level and two rulers, or by using a roof pitch card. from a lower living space into an attic space where the chimney is See figure below.
  • Page 44: Vertical Venting Over 15 Feet

    Vertical Venting over 15 Feet The Air Intake plate must be adjusted down to the lowest position when venting over 15 ft. vertical. 15ʼ OR OVER VERTICAL VENTING AIR INTAKE ADJUSTMENT PLATE NOTE: Unit comes preset for short horizontal or vertical venting under a 15 feet run. Follow these instructions when venting exceeds 15 foot run.
  • Page 45: Mqzdv3318 Parts List

    Surround Flat Pewter RMCBP Remote Control - Basic - Liquid Propane (Coverage 35 5/16” H x 45 13/16” W) (On/Off, Hi/Lo Flame Adjustment) Marquis Wall Surround Accents (Four Pieces) DCHS Remote Control Heatshield MQ33SWAKSB Wall Surround Accents - Keystone Black VLBIT4...
  • Page 46: Mqzdv3622 Parts List

    RMCBN Remote Control - Basic - Natural Gas (On/Off,Hi/Lo Flame Adjustment) (Coverage 37 5/32” H x 50 5/16” W) Marquis Wall Surround Accents (Four Pieces) RMCBP Remote Control - Basic - Liquid Propane (On/Off, Hi/Lo Flame Adjustment) MQ36SWAKSB Wall Surround Accents - Keystone Black...
  • Page 47: Common Parts & Venting

    Parts ZDV3318 / MQZDV3318 / ZDV3622 / MQZDV3622 / ZDVRB3622 Catalog 1000-227 Cover Ivory (86001/001) Number Description 1000-255 Orifice Brass - (State Size) Valve System Parts - New Top convertible SIT (Millivolt) 6000-130 Explosion felt Gasket FP15GC Stainless Steel Gas Connector...
  • Page 48: Glass Safety / Termination Cap Safety- All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. Optional safety screens are available for most appliances. Check with your dealer to find out if one is available for your unit, or if an aftermarket free standing safety screen is available.
  • Page 49: Limited Lifetime Warranty

    LIMITED LIFETIME WARRANTY This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed inside the continental United States, Alaska, Hawaii, and Canada. The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable installation and building codes and good trade practices.

This manual is also suitable for:

Solara mqzdv3622

Table of Contents