Marquis Solace MQHBZDV3636 Installation Instructions Manual

Solace/skyline zero clearance direct vent gas fireplace
Hide thumbs Also See for Solace MQHBZDV3636:
Table of Contents

Advertisement

Model Numbers: MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T,MQHBZDV4736
Stock #'s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQRB4236LP, MQHBZDV4236LP,
MQHBZDV3636NE, MQHBZDV3636LPE, MQHBZDV4236NE, MQRB4236NE, MQRB4236LPE, MQHBZDV4236LPE
Certified to: ANZI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
Stock #'s: MQRB4236NT, MQRB4236LPT, MQHBZDV4736N, MQHBZDV4736LP,
MQRB4236NTE, MQRB4236LPTE, MQHBZDV4736NE, MQHBZDV4736LPE,
Certified to:
ANSI Z21.50b-2009, CSA 2.22b-2009,
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before
going horizontal.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada
August 16,2010
SOLACE/SKYLINE

Installation Instructions

Zero Clearance Direct Vent Gas Fireplace
Listed Certified for USA. and Canada
Read this complete manual before beginning installation.
FOR YOUR SAFETY
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Part # 36MQ-MAN
CGA 2.17-M91

Advertisement

Table of Contents
loading

Summary of Contents for Marquis Solace MQHBZDV3636

  • Page 1: Installation Instructions

    Installation Instructions Zero Clearance Direct Vent Gas Fireplace Listed Certified for USA. and Canada Model Numbers: MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T,MQHBZDV4736 Stock #’s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQRB4236LP, MQHBZDV4236LP, MQHBZDV3636NE, MQHBZDV3636LPE, MQHBZDV4236NE, MQRB4236NE, MQRB4236LPE, MQHBZDV4236LPE Certified to: ANZI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91 Stock #’s: MQRB4236NT, MQRB4236LPT, MQHBZDV4736N, MQHBZDV4736LP,...
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    Gas Conversion for Modulator – PART C................IPI Electronic Ignition System....................41-45 IPI Lighting Instructions......................Door and Glass Information....................Log Placement - LOGF36..................... MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236......49-50 MQROCK1/MQRSP1 Setup for Models MQHBZDV4736............ 51-52 Accessories for MQRB3328, MQRB3632, MQRB4236............Vent Termination........................
  • Page 4: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 5: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 7: Mqhbzdv3636 - Locating Your Appliance

    MQHBZDV3636 - Locating your Appliance Installing with Top Vent A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall...
  • Page 8: Framing For Your Gas Fireplace

    MQHBZDV3636 - Framing for your Gas Fireplace Framing Specifications 4. When installing horizontal with a 90 degree bend maintain a mini- mum of two and a half (2.5”) inches above the bend in enclo- 1. Cold climate installation recommendation: When installing this fire- sures.
  • Page 9: Framing And Facing Requirements

    MQHBZDV3636 - Framing and Facing Requirements HBZDV36 WITH HB36CVCK (CLEAN VIEW CIRCULATING KIT) HB36CVCK WITH MQHB36SW SURROUND...
  • Page 10: Installing Clean View Kit (Cvck)

    MQHBZDV3636 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly. Install optional fan kit (see Fan Instruction). Fold two standoffs up into position and mount with supplied screws. (FIG 1) Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2) Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
  • Page 11: Parts List

    MQHBZDV3636 Parts List Child Safety Screens Fireplace Part Numbers HB36CSS Child Safety Screen - 36” HBZDV Fireplaces MQHBZDV3636N (Millivolt) Fireplace Heater Rated NG, Ceramic HB36PSK Pull Screen Kit for CVCK MQHBZDV3636NE (IPI) Glass, 30,500 BTU AT 75% efficient. Overlays Approved for bedroom and mobile home.
  • Page 12: Kingsman Fireplace Venting

    MQHBZDV3636 Parts List Kingsman Fireplace Venting Catalog Electronic Ignition Replacement Parts IPI Number Description 1002-P001si Valve IPI (NG; ON/OFF) ZDVHSK Horizontal Vent Starter Kit - 3 FT Length 1002-P002si Valve IPI (LP; ON/OFF) Horizontal Vent Termination, Wall Thimble, 36” Flex Pipe, Mill Pac, screws/washers, springs.
  • Page 13: Locating Your Appliance

    MQHBZDV4236/MQRB4236 - Locating your Appliance A - Flat on a wall D - As a room divider Installing with Top Vent B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 14: Framing For Your Gas Fireplace

    MQHBZDV4236/MQRB4236 - Framing for your Gas Fireplace Framing Specifications 4. When installing horizontal with a 90 degree bend maintain a minimum 1. Cold climate installation recommendation: When installing this fire- of two and a half (2.5”) inches above the bend in enclosures. place against non insulated exterior wall or chase, it is recom mended 5.
  • Page 15: Framing And Facing Requirements

    MQHBZDV4236/MQRB4236 - Framing and Facing Requirements HBZDV42 WITH HB42CVCK (CLEAN VIEW CIRCULATING KIT) HB42CVCK WITH MQHB42SW SURROUND *Note: A HBCVCK must be used when installing a MQHBSW Wall Surround.
  • Page 16: Installing Clean View Kit (Cvck)

    Side & Bottom of Horizontal Pipe 1 inch/25.5mm / All Vent Systems View Circulating Kit) see Vertical Vent Pipe 1 inch/25.5mm / Kingsman Vent Systems framing with CVCK to Vertical Vent Pipe 1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk establish floor heights...
  • Page 17: Parts List

    Rock Set Multi-Color (HBZDV/MQRB) RMCBN Remote Control - Basic - Natural Gas MQRSP2 Rock Platform, Support and 4 Screws (On/Off, Hi/Lo Flame Adjustment) (MQHBZDV3636, MQHBZDV4236) RMCBP Remote Control - Basic - Liquid Propane MQEMBER Glowing Embers, 2 ea. (MQRB4236) (On/Off, Hi/Lo Flame Adjustment)
  • Page 18: Kingsman Fireplace Venting

    Conversion Kit (Sit Valve Only) IPI Kingsman Fireplace Venting 4232HB-CKLPI LP Conversion Kit for MQHBZDV4236 (IPI) 4232HB-CKNGI NG Conversion Kit for MQHBZDV4236 (IPI) Catalog Number Description 4236RB-CKNGI NG Conversion Kit for MQRB4236 (IPI) ZDVHSK Horizontal Vent Starter Kit - 3 FT Length...
  • Page 19: Locating Your Appliance

    MQHBZDV4736 - Locating your Appliance A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner Installing with Top Vent C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 20: Framing For Your Gas Fireplace

    MQHBZDV4736 - Framing for your Gas Fireplace Framing Specifications sleeve is required. If greater than six and a half (6.5”) an insulation sleeve is not required. 1. Cold climate installation recommendation: When installing this fire- place against non insulated exterior wall or chase, it is recom mended 5.
  • Page 21: Framing And Facing Requirements

    MQHBZDV4736 - Framing and Facing Requirements HBZDV47 WITH HB47CVCK (CLEAN VIEW CIRCULATING KIT) HB47CVCK WITH MQHB47SW SURROUND...
  • Page 22: Installing Clean View Kit (Cvck)

    View Circulating Kit) see Side & Bottom of Horizontal Pipe 1 inch/25.5mm / All Vent Systems framing with CVCK to Vertical Vent Pipe 1 inch/25.5mm / Kingsman Vent Systems establish floor heights Vertical Vent Pipe 1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp Systems...
  • Page 23: Parts List

    MQHBZDV4736 - Parts List Overlays Fireplace Part Numbers MQHBZDV4736N (Millivolt) Fireplace Decorative Rated NG, HB47ADTH Arch Door Top Half Black MQHBZDV4736NE (IPI) Tempered Glass, 40,000 BTU HB47ADDX Arch Door Frame - Deluxe Black MQHBZDV4736LP (Millivolt) Fireplace Decorative Rated LP, HB47ADDA Arch Door Frame - Double Arch Black MQHBZDV4736LPE (IPI) Tempered Glass, 40,000 BTU...
  • Page 24: Kingsman Fireplace Venting

    Kingsman Fireplace Venting Electronic Ignition Replacement Parts IPI 1002-P001si Valve IPI (NG; ON/OFF) Catalog 1002-P002si Valve IPI (LP; ON/OFF) Number Description 1006-P002si Valve IPI (NG; Hi/Lo) ZDVHSK Horizontal Vent Starter Kit - 3 FT Length 1006-P603si Valve IPI (LP; Hi/Lo) Horizontal Vent Termination, Wall Thimble, 36”...
  • Page 25: Clearance, Mantels & Surrounds

    CLEARANCES - MQHB36/42/47/MQRB4236 - Mantels & Surrounds WARNING: Combustible objects must not be placed on a non-combustible mantel unless the non-combustible mantel meets the minimum height and width require ments for a combustible mantel.
  • Page 26: Mantel Leg Clearances

    Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using MQHBSW.
  • Page 27: Dimensions & Installations Of Wall Mount Surrounds

    MQSW Wall Mount Surround Dimensions Concave Convex HB36 HB36 HB42 HB42 HB47 HB47 Installation of MQ Wall Mount Surrounds Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Remove the old CAP (Control Access Panel), and the Lower CVCK panel by unscrewing the...
  • Page 28: Fan Installation

    Fan Installation for HBZDV 36/42/47 Fan Installation instructions for HBZDV36/42/47 3. Wire Junction Box to 120v and wall mounted variable speed control. Install a duplex outlet to junction box and plug fan into outlet. with or without CVCK (Clean View Circulating Kit) 4.
  • Page 29: Installing Mqrb4236 Liner Panels

    Installing MQRB4236 Liner Panels...
  • Page 30: Brick Installation

    Brick. Side brick must be flush with side wall of Firebox. Rotate clip down over Brick Panel and tighten screw. NOTE: Side Brick for MQHBZDV3636 & MQHBZDV4236 Top of side brick has to be tilted forward and hooked over bottom front lip of Firebox first then rotated backward into position.
  • Page 31: Installation Of Hb Porcelain Liners - Hb36Pl/Hb42Pl/Hb47Pl

    Installation of HB Porcelain Liners - HB36PL/HB42PL/HB47PL 1. Remove Door from the fireplace by unlatching the 2 latches on top of unit. 2. Remove back Log Holder by removing 3 screws from face of Log Holder. The Log Holder will have to be re- installed after the placement of the Back Panel.
  • Page 32: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1.
  • Page 33: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When •...
  • Page 34: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 35: Burner System Removal For Mqhb36/42/47

    New sealant will have to be applied when re-installing access cover and burner system to maintain the integrity of sealed com- bustion chamber. Mil Pac part #840099 or Kingsman part #1000-150MP sealant can be purchased from your Kingsman retailer or distributor.
  • Page 36: Burner System Maintenance

    The pilot flame should also be inspected monthly to ensure proper operation. Flame should appear similar to the above picture – Solace Series (MQHBZDV3636, MQHBZDV4236, MQHBZDV4736) Flame should appear similar to the above picture- Skyline Series (MQRB4236)
  • Page 37: Conversion Kit Instructions - Part A

    Conversion Kit Instructions – PART A Burner Orifice Kit Number Description Pilot Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) 3632HB -CKLP 1001-P167SI 1001-P202SI Conversion 1000-253closed 5/16” #30 (977.167) (0.907.202) MQHBZDV3636LP -Millivolt- 3632HB –CKLPI 1001-P168SI 1002-P014SI Conversion 1000-253closed 5/16” #35 (977.168) (0.907.014) MQHBZDV3636LPE...
  • Page 38 MQHB3636/4236/4736 Gas Conversion –Part A WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instruction s and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 39: Gas Conversion For Top Convertible Pilot (Series 019065X) - Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 40: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 41: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 42 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 43 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 44 Configuration #2: Remote ON/OFF and manual HI/LO capabilities. OPTIONAL: For units with remote HI/LO capabilities, a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown in the figure above.
  • Page 45 Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 46: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 47: Door And Glass Information

    Tempered Glass. Must be 5mm thick. Only Robax ceramic or coated Neaoceram glass may be used for replacement for model MQHBZDV3636, MQHBZDV4236 and MQRB4236. Must be minimum 5mm thick. To replace glass, clean all materials from door frame. Scrape off old silicone down to metal.
  • Page 48: Log Placement - Logf36

    LOG PLACEMENT - LOGF36 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST STEP 1: Place log #1 onto rear log holder and center.
  • Page 49: Mqrock1/Mqrsp2 Setup For Models Mqhbzdv3636/Mqhbzdv4236

    MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST STEP 1: Remove the log holder mount, log supports, and STEP 2: Attach the back rock support with the 4 screws the grate bar.
  • Page 50 MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 STEP 5: Place rocks #1 onto the burner as shown. STEP 6: Place rocks #3 onto the burner as shown. STEP 7: Place rocks #4 onto the burner as shown. STEP 8: Place rocks #6 onto the burner as shown.
  • Page 51: Mqrock1/Mqrsp1 Setup For Models Mqhbzdv4736

    MQROCK1/MQRSP1 Setup for Models MQHBZDV4736 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST: Rock #1 - 5 pieces; Rock #3 - 6 pieces;...
  • Page 52: Mqrock1/Mqrsp1 Setup For Models Mqhbzdv4736

    MQROCK1/MQRSP1 Setup for Models MQHBZDV4736 STEP 6: Place rocks #4 into position as shown. STEP 5: Place rocks #3 into position as shown. Do not place rocks directly onto the burner tubes. STEP 7: Place rocks #6 into position as shown. STEP 8: Place remaining rocks #4 and #6 into position as shown.
  • Page 53: Accessories For Mqrb3328, Mqrb3632, Mqrb4236

    Accessories for MQRB3328, MQRB3632, MQRB4236 Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. The following options are available for the MQRB Series. Each option may be used independently or in combination with any other.
  • Page 54: Vent Termination

    (30cm) minimum This appliance is approved with Kingsman flex vent system and G - Clearance from a perpendicular inside wall or outer corner to also approved for use with Simpson Duravent Direct Vent the edge of the vent terminal plate is 3”...
  • Page 55: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z- Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure- Seal DV and Selkirk Direct Temp.
  • Page 56: Venting Table

    How To Use The Horizontal Vent Table Venting Routes And Components Since it is very important that the vent system maintain its bal- 1. Determine the height of the system and the number of bends ance between the combustion air intake and the flue gas required.
  • Page 57: Installation Of Side Wall Venting

    Note: Wall Thimble cover combustible wall up to 11” thick. Note: Venting termination must not be recessed into wall or siding. MQHBZDV4736 Minimum clearance to combustibles on venting Vertical 1” with Kingsman Vent System MQHBZDV4236/MQRB4236 1 1/4” with Simpson Duravent Systems Top of Horizontal Pipe 1 1/2”...
  • Page 58: Vertical Venting

    Venting Straight Up Through Roof Roof Flashing Ensure that you have the proper roof flashing by checking your 1. An Attic Insulation Shield must be installed where the vent passes roof pitch using a level and two rulers, or by using a roof pitch card. from a lower living space into an attic space where the chimney is See figure below.
  • Page 59: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents