Marquis SOLACE Installation Instructions Manual

Hide thumbs Also See for Marquis SOLACE:
Table of Contents

Advertisement

Model Numbers: MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T, HBZDV4736
Stock #'s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQHBZDV4236LP,
MQHBZDV3636NE, MQHBZDV3636LPE, MQHBZDV4236NE, MQRB4236NE, MQHBZDV4236LPE
Certified to: ANSI Z21.88-2014 • CSA 2.33-2014ZERO CLEARANCE VENTED GAS FIREPLACE HEATER
Stock #'s: MQRB4236NT, MQRB4236LPT, MQRB4236NTE, MQRB4236LPTE
HBZDV4736N, HBZDV4736LP,HBZDV4736NE, HBZDV4736LPE
Certified to: ANSI Z21.50-2014 • CSA 2.22-2014 ZERO CLEARANCE VENTED GAS FIREPLACE
SOLACE/SKYLINE
Installation Instructions
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
For Propane Horizontal installations the venting
must be a minimum of one foot vertical off the
flue before going horizontal.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada September 4, 2018
Part # 36MQ-MAN14

Advertisement

Table of Contents
loading

Summary of Contents for Marquis Marquis SOLACE

  • Page 1 SOLACE/SKYLINE Installation Instructions Model Numbers: MQHBZDV3636, MQHBZDV4236, MQRB4236, MQRB4236T, HBZDV4736 Stock #’s: MQHBZDV3636N, MQHBZDV3636LP, MQHBZDV4236N, MQRB4236N, MQHBZDV4236LP, MQHBZDV3636NE, MQHBZDV3636LPE, MQHBZDV4236NE, MQRB4236NE, MQHBZDV4236LPE Certified to: ANSI Z21.88-2014 • CSA 2.33-2014ZERO CLEARANCE VENTED GAS FIREPLACE HEATER Stock #’s: MQRB4236NT, MQRB4236LPT, MQRB4236NTE, MQRB4236LPTE HBZDV4736N, HBZDV4736LP,HBZDV4736NE, HBZDV4736LPE Certified to: ANSI Z21.50-2014 •...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents……………………………………………………………........Pre-installation Questions and Answers…………………………………........Operating Instructions………………………………………………………........Safety Screen Installation…………………………………………………………………………… Mobile Home/Manufactured Housing Installation……………………........Warnings, Installations, and Operations…………………………………........Installation Requirements for the Commonwealth of Massachusetts…........Fireplace Installations in Covered Outdoor Locations............. MQHBZDV3636 Locating your Appliance................Fireplace Dimensions.................
  • Page 3: Table Of Contents

    Table of Contents (Continued) Configuration 2- Remote ON/OFF................... Configuration 3- Remote ON/OFF, Variable Hi/Lo, and Fan........... IPI Lighting Instructions......................PROFLAME 2 Parts List, GTMFL System....................... IFC Module and Remote Control..................... Cold Climates – CPI Setting....................Flame Control, Room Thermostat................... Smart Thermostat, Fan Speed Control, Light Control............. Label Schematic........................
  • Page 4: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 5: Safety Screen Installation

    Safety Screen Installation Z Series Contents of Kit: [1] Safety Screen [2] Side Angles [2] Horizontal Angles [12-16] DT Screws (Depending on screen size) Assembly: Attach components with supplied screws as shown. NOTE: Screens are symmetrical from top to bottom. ⚠...
  • Page 6: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 7: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 8: Installation Requirements For The Commonwealth Of Massachusetts

     Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source.  This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 9: Fireplace Installations In Covered Outdoor Locations

    Fireplace Installations in Covered Outdoor Locations Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement. However, all installation clearances in the appliance manual must be observed. Framing, Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc.
  • Page 10: Locating Your Appliance

    Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 11: Framing For Your Gas Fireplace

    MQHBZDV3636 - Framing for your Gas Fireplace 4. When installing horizontal with a 90 degree bend maintain a mini- Framing Specifications mum of two and a half (2.5”) inches above the bend in enclo- 1. Cold climate installation recommendation: When installing this fire- sures.
  • Page 12: Framing And Facing Requirements

    HBZDV36 - Framing and Facing Requirements HBZDV36 WITH HB36CVCK (CLEAN VIEW CIRCULATING KIT) Non Combustible Header Attached Non Combustible Header Attached HB36CVCK WITH MQHB36SW SURROUND Non Combustible Header Non Combustible Header Attached...
  • Page 13: Installing Clean View Kit (Cvck)

    HB36 - How to Install Clean View Kit (CVCK) For HB36/HB42/HB47 CAUTION: When using CVCK DO NOT INSTALL a Louver assembly. Install optional fan kit (see Fan Instruction). Fold two standoffs up into position and mount with supplied screws. (FIG 1) Hang CVCK on top of fireplace retainer tabs and rotate down into position.
  • Page 14 HBZDV3636 Parts List Fireplace Part Numbers Z80PT Thermostat Programmable Digital Millivolt Wall Mount (1F80-40) Fireplace Heater Rated NG, Ceramic HBZDV3636N (Millivolt) Glass, 30,500 BTU AT 75% efficient. GTRC Remote Control Millivolt - Thermostat HBZDV3636NE (IPI) Approved for bedroom and mobile GTMRCP Remote Control Millivolt –...
  • Page 15: Parts List

    MQHBZDV3636 Parts List Kingsman Fireplace Venting Catalog Electronic Ignition Replacement Parts IPI Number Description 1002-P001si Valve IPI (NG; ON/OFF) ZDVHSK Horizontal Vent Starter Kit - 3 FT Length 1002-P002si Valve IPI (LP; ON/OFF) Horizontal Vent Termination, Wall Thimble, 1006-P002si Valve IPI (NG; Hi/Lo) 36”...
  • Page 16: Locating Your Appliance

    Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 17: Framing For Your Gas Fireplace

    MQHBZDV4236/MQRB4236 - Framing for your Gas Fireplace 4. When installing horizontal with a 90 degree bend maintain a minimum Framing Specifications 1. Cold climate installation recommendation: When installing this fire- of two and a half (2.5”) inches above the bend in enclosures. place against non insulated exterior wall or chase, it is recom mended 5.
  • Page 18: Framing And Facing Requirements

    HB42 - Framing and Facing Requirements HBZDV42 WITH HB42CVCK (CLEAN VIEW CIRCULATING KIT) Non Combustible Header Attached Non Combustible Header Attached HB42CVCK WITH MQHB42SW SURROUND *Note: A HBCVCK must be used when installing a MQHBSW Wall Surround.
  • Page 19: Installing Clean View Kit (Cvck)

    HB42 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly. Install optional fan kit (see Fan Instruction). Fold two standoffs up into position and mount with supplied screws. (FIG 1) Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2) Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
  • Page 20: Mqhbzdv4236/Mqrb4236

    MQHBZDV4236/MQRB4236 Parts List HB42SLCR Surround Slim Line - Chrome Fireplace Part Numbers (Coverage 37 3/8” H x 43 3/8” W) MQHBZDV4236N (Millivolt) Fireplace Heater Rated NB, HB42SLPB Surround Slim Line - Polish Brass Ceramic (Coverage 37 3/8” H x 43 3/8” W) MQHBZDV4236NE(IPI) Glass 30,500 BTU at 75% efficient.
  • Page 21: Kingsman Fireplace Venting Parts

    1000-306 Thermalcord - Adhesive Back for Door Frame 42HB-310 Ceramic Glass 4236RB-SRKP* Upgrade Kit 36HB-123 Upper Door Spring *NOTE: THE MQRB4236N CANNOT BE CONVERTED TO LP. OFP42SA Spark Assist If the MQRB4236NT you wish to convert to LP has a serial Kingsman Fireplace Venting number less than #4708 You MUST order the 4236RB-SRKP upgrade kit.
  • Page 22: Locating Your Appliance

    Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 23: Framing For Your Gas Fireplace

    MQHBZDV4736 - Framing for your Gas Fireplace sleeve is required. If greater than six and a half (6.5”) an insulation sleeve Framing Specifications is not required. 1. Cold climate installation recommendation: When installing this fire- place against non insulated exterior wall or chase, it is recom mended 5.
  • Page 24: Framing And Facing Requirements

    Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached...
  • Page 25: Installing Clean View Kit (Cvck)

    HB47 - HOW TO INSTALL CLEAN VIEW KIT (CVCK) CAUTION: When using CVCK DO NOT INSTALL a Louver assembly. Install optional fan kit (see Fan Instruction). Fold two standoffs up into position and mount with supplied screws. (FIG 1) Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2) Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
  • Page 26 HBZDV4736 - Parts List OPTIONAL THERMOSTATS AND REMOTE CONTROLS ZERO CLEARANCE DIRECT VENT GAS FIREPLACES 47” WIDE *In the U.S.A. Thermostats are not permitted for Listed for USA / Canada, Dual Burner, Millivolt SIT Vented Gas Fireplaces (ANSI Z21.50b) Valve with Hi/Lo Adjustment, Wall Switch, Tempered Z2MT Thermostat Digital –...
  • Page 27: Kingsman Fireplace Venting Parts

    Safety Cage for Horizontal Piezo-Igniter 1244-17 MARK 21 1000-214 FDVHSCU Termination Pal Nut (18MMXI.5MM)BLK (1364.03) 1000-215 Switch Ivory (1451/001) Attic Insulation Shield 1000-218 ZDVAIS Cover Ivory (86001/001) 1000-227 Attic Insulation Shield 24” Z7AIS24 Orifice Brass - (State Size) 1000-255 Offset Support ZDVVOS Thermodisc 2450 (For Blower) 2000-080...
  • Page 28: Common Section Clearance, Mantels & Surrounds

    Clearances – HB36 / HB42 / HB47 – Mantels & Surrounds Warning: Combustible objects must not be placed on a non-combustible mantel unless the non- combustible mantel meets the minimum height and width requirements for a combustible mantel. Note For the installation of the MQHBSW.
  • Page 29 Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using MQHBSW.
  • Page 30: Dimensions & Installations Of Wall Mount Surrounds

    MQSW Wall Mount Surround Dimensions Concave Convex HB36 HB36 HB42 HB42 HB47 HB47 Installation of MQ Wall Mount Surrounds Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Remove the old CAP (Control Access Panel), and the Lower CVCK panel by unscrewing the...
  • Page 31: Parts List

    Fan Installation for HBZDV 36/42/47 3. Wire Junction Box to 120v and wall mounted variable speed control. Fan Installation instructions for HBZDV36/42/47 Install a duplex outlet to junction box and plug fan into outlet. with or without CVCK (Clean View Circulating Kit) 4.
  • Page 32: Split Receptacle- Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 33: Installing Mqrb4236 Liner Panels

    Installing MQRB4236 Liner Panels There are several types of Liner Panels available for the MQRB4236: -Flat Black Back Panel and False Bottom- (Supplied with Unit). -Porcelain Back and Side Panels- MQRB42PL Removal of False Bottom and Back Panel Remove four [4] screws from False Bottom and lift out of the Firebox (Ref.1). The Back Panel is held in place by the False Bottom and 2 Locking Tabs on the inside top of the Firebox (See Ref.2 Below).
  • Page 34: Brick Installation

    Brick Installation - For Models MQHBZDV3636 / MQHBZDV4236 / HBZDV4736 INSTALLING BRICK PANELS FOR MODEL MQHBZDV3636 / MQHBZDV4236 / HBZDV4736 1. Remove door glass from the unit by unlatching the 2 latches on top of unit. 2. (MQHBZDV4736 ONLY) Using a 1/4” nut driver remove two screws from Brick Panel Filler (#1) and discard brick panel filler. (Ref.1) 3.
  • Page 35: Installation Of Hb Porcelain Liners - Hb36Pl/Hb42Pl/Hb47Pl

    Installation of HB Porcelain Liners - HB36PL/HB42PL/HB47PL 1. Remove Door from the fireplace by unlatching the 2 latches on top of unit. 2. Remove back Log Holder by removing 3 screws from face of Log Holder. The Log Holder will have to be re- installed after the placement of the Back Panel.
  • Page 36: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A.
  • Page 37: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When ...
  • Page 38: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. WARNING: NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 39: Burner System Removal For Mqhb36/42/47

    Burner System Removal for MQHB36/42/47 Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Removing Burner System / Access Cover for MQHBZDV36/42/47 If fireplace has been installed with optional CVCK (Clean View Circulating Kit) to service fan system or burner system controls, the access cover and burner system pan will have to be removed.
  • Page 40: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 41: Conversion Kit Instructions - Part A

    Conversion Kit Instructions – PART A Burner Orifice Kit Number Description Pilot Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) 3632HB -CKLP 1001-P167SI 1001-P202SI Conversion 1000-253closed 5/16” #30 (977.167) (0.907.202) MQHBZDV3636LP -Millivolt- 3632HB –CKLPI 1001-P168SI 1002-P014SI Conversion 1000-253closed 5/16” #35 (977.168) (0.907.014) MQHBZDV3636LPE...
  • Page 42 MQHB3636/4236 / HBZDV4736 Gas Conversion –Part A WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instruction s and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 43: Gas Conversion For Top Convertible Pilot (Series 019065X) - Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 44: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 45: Door And Glass Information

    Door and Glass Information Removal of the Glass Door Glass Cleaning 1. Remove the door by unlatching the 2 top latches. Simply It will be necessary to clean the glass periodically. During start- place 2 fingers in the grooves, pull towards you and lift up, condensation, which is normal, forms on the inside of the upwards slightly.
  • Page 46: Log Placement - Logf36

    LOG PLACEMENT - LOGF36 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST STEP 1: Place log #1 onto rear log holder and center.
  • Page 47: Pilot Shield Rsp1 / Rsp2

    Pilot Shield RSP1 / RSP2 Qty: 1 Shield Per Kit SLOTS SLOTS Back View SLOTS SLOTS...
  • Page 48: Mqrock1/Mqrsp2 Setup For Models Mqhbzdv3636/Mqhbzdv4236

    MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST STEP 1: Remove the log holder mount, log supports, and STEP 2: Attach the back rock support with the 4 screws the grate bar.
  • Page 49 MQROCK1/MQRSP2 Setup for Models MQHBZDV3636/MQHBZDV4236 STEP 5: Place rocks #1 onto the burner as shown. STEP 6: Place rocks #3 onto the burner as shown. STEP 7: Place rocks #4 onto the burner as shown. STEP 8: Place rocks #6 onto the burner as shown. STEP 9: Place remaining rocks #4 and #6 into position as Finished Rock F2 Setup shown.
  • Page 50: Mqrock1/Mqrsp1 Setup For Models Hbzdv4736

    MQROCK1 / MQRSP1 Setup for Model HBZDV4736 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST: Rock #1 - 5 pieces; Rock #3 - 6 pieces;...
  • Page 51 MQROCK1 / MQRSP1 Setup for Model HBZDV4736 STEP 6: Place rocks #4 into position as shown. STEP 5: Place rocks #3 into position as shown. Do not place rocks directly onto the burner tubes. STEP 7: Place rocks #6 into position as shown. STEP 8: Place remaining rocks #4 and #6 into position as shown.
  • Page 52: Accessories Available For Skyline & Zdvrb3622 Ribbon Burner Units

    Accessories for Skyline, ZDVRB3622, & ZRB46 Ribbon Burner Units ACCESSORY ITEM MQRB3632 MQRB4236 ZDVRB3622 White Glass MQG5W Yes / 5LB MAX 5LB Bag c/w Unit MQ Dealer Only Bronze Glass Yes / 5LB MAX Yes / 5LB MAX 5LB Bag c/w MQG5C Unit Cobalt Blue Glass...
  • Page 53: Ulk2 Universal Light Kit (Optional Accent Lighting Kit)

    ⚠ NOTE: Glass Media must be evenly spread over the Burner and False Bottom as described on last page before Rock / Stones / and Log Accessories are placed.  MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom. Be careful not to cover any part of the Burner Tube as sooting may occur.
  • Page 54 ULK2 Universal Light Kit ( Optional Accent Lighting Kit) For the Skyline Series (MQRB3328, MQRB3632, MQRB4236) and Kingsman ZDVRB3622 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Contents of Kit: ...
  • Page 55 MQRB3328, ZDVRB3622, & MQRB4236 Screw Screw MQRB3632 Screw Screw STEP 3: Place Lamps in position in firebox. Attach to fireplace with a single screw at the locations shown above for each unit. Lamps can be placed facing upward or sideways. Replace burner tube and false bottom, along with pilot shield.
  • Page 56: Overview And Components

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 57 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 58: Configuration 1- Basic

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 59: Configuration 2- Remote On/Off

    Configuration #2: Remote ON/OFF and manual HI/LO capabilities. OPTIONAL: For units with remote HI/LO capabilities, a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown in the figure above.
  • Page 60: Configuration 3- Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 61: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 62: Proflame 2 Parts List, Gtmfl System

    Proflame 2- Parts List- Basic System, Parts List, Configuration GTMFL ITEM PART DESCRIPTION NUMBER 1005-P001si IPI Valve NG with Stepper Motor 885.001 1005-P002si IPI Valve LP with Stepper Motor 885.001 1006-P002si IPI Valve NG Hi / Lo 1006-P003si IPI Valve LP Hi / Lo 1002-P033si Pilot NG IPI 199.059 1005-P325si...
  • Page 63: Ifc Module And Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button Within 10 seconds press the button again until  Pairing Remote Control: you hear it beep. ...
  • Page 64: Cold Climates - Cpi Setting

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a LCD Display flame. The CPI (Continuous Pilot Ignition) setting will keep the ON / OFF Key firebox and fireplace exhaust vent warm during cold weather.
  • Page 65: Flame Control, Room Thermostat

    Proflame 2 Remote Control...
  • Page 66: Smart Thermostat, Fan Speed Control, Light Control

    Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 68: Vent Termination

    Vent Termination WARNING: A HORIZONTAL VENT Notes: Area Where Terminal Not Permitted. CERTIFIED GUARD 1) Clearances are to the edge of the terminal (SAFETY CAGE) IS plate. Add 6-3/4” to clearances to arrive at Air Supply centerline. AVAILABLE WHEN Measure to edge of the Termination Plate REQUIRED BY LOCAL 2) Local codes or regulations may require Measure to edge of the Round Termination...
  • Page 69: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex(Z- Flex)Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure- Seal DV and Selkirk Direct Temp.
  • Page 70: Venting Table

    How To Use The Horizontal Vent Table Venting Routes And Components Since it is very important that the vent system maintain its bal- 1. Determine the height of the system and the number of bends ance between the combustion air intake and the flue gas required.
  • Page 71: Installation Of Side Wall Venting

    Installation Of Side Wall Venting 1. Establish the minimum distance from the bottom of fireplace to centre MQHBZDV3636 of vent. Cut a hole through the wall allowing for a 11” x 11” (inside diameter) in combustible walls for wall thimble or an 8” diameter hole in a non-combustible wall (See Figure 1-2-3).
  • Page 72: Vertical Venting

    Venting Straight Up Through Roof Roof Flashing Ensure that you have the proper roof flashing by checking your 1. An Attic Insulation Shield must be installed where the vent passes roof pitch using a level and two rulers, or by using a roof pitch card. from a lower living space into an attic space where the chimney is See figure below.
  • Page 73: Glass Safety / Termination Cap Safety- All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 74: Approved For Power Vent Pvh58

    Approved for Power Vent PVH58 - This appliance is approved for use with the Kingsman PVH58 Horizontal Power Vent - The PVH58 Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 75: Pvh58 Power Vent Parts List

    PVH58 POWER VENT PARTS LIST NUMBER DESCRIPTION PVH58 Horizontal Power Vent Termination Power Vent Control Module – Millivolt Box PVC58MV Power Vent Control Module – IPI Box PVC58IPI Main Wiring Harness Assembly – Extension Harness (20ft) PVH20H 4/7 VENTING AND VENTING ADAPTERS For fireplaces to be converted to hard pipe (Duravent-DirectVent Pro, etc.) at the fireplace: Duravent Fireplace Adapter (ZRB46 Only) ZDVDKA...
  • Page 76: Limited Lifetime Warranty

    This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed inside the continental United States, Alaska, Hawaii, and Canada. The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable installation and building codes and good trade practices.

Table of Contents