Ipi Lighting Instructions - Marquis Solace MQHBZDV3636 Installation Instructions Manual

Solace/skyline zero clearance direct vent gas fireplace
Hide thumbs Also See for Solace MQHBZDV3636:
Table of Contents

Advertisement

1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or
removed.
A. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light by hand.
B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control system and any gas control which has been under water
1. Turn off all gas to the fireplace.
2. Open windows.
3. Do not try to light any appliance.
4. Do not touch any electric switch; do not use any
phone in your building
1. STOP! Read the above safety information on this label.
2. Remove batteries from Receiver and/or Battery Backup Pack.
3. Turn off all electric power to the fireplace.
4. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot
by hand.
5. Open the glass door.
6. Turn manual shutoff valve clockwise
7. Wait five [5] minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" in the above
safety information on this label. If you don't smell gas go to the next step.
8. Turn manual shutoff valve counter-clockwise
9. Close the glass door.
10. Turn on all electric power to the fireplace, and re-install batteries into the Transmitter/Receiver and/or Battery
Backup Pack.
11. Turn ON the switch that operates the Main Burner. If using a Remote Control refer to Remote Control Operation
Manual for activation.
1. Turn OFF all electric power to the fireplace if service is to be performed, including removing batteries from the
Remote Transmitter/Receiver and/or Battery Backup Pack.
2. Access door inside the firebox must be removed to access the manual shutoff valve.
3. If alternate shut-off valve was installed it can be shutoff instead of going through the fireplace to access the fire-
place shut off valve.

IPI Lighting Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING
WHAT TO DO IF YOU SMELL GAS
.
LIGHTING INSTRUCTIONS
to OFF position (located behind the access panel).
TO TURN OFF GAS
WARNING
5. Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
6. If you cannot reach your gas supplier, call the fire
department.
to ON position.