COMMISSIONING

Start the water flow by rotating the flow control
(left hand side) anticlockwise.
Make sure that the hot and cold water supplies
are fully open and at (or near to) their design
temperature and pressures, and are within the
requirements as stated on pages 2 & 14.
Make sure the temperature control (right hand
side) is at the maximum temperature setting
WITHOUT operating the maximum temperature
override button.
Allow the shower to run at this maximum
temperature setting until the water temperature
has stabilised.
Rotate the temperature control until your desired
maximum showering temperature is reached.
NOTE: If your desired temperature is above
the maximum temperature stop limit,
please see ADJUSTING THE MAXIMUM
TEMPERATURE STOP SETTING section.
A final temperature check SHOULD be made on-
site to guarantee user safety, and that the mixer
falls within recommended maximum mixed
water outlet temperatures as stated on page
11.

FLOW REGULATION

A flow regulator is supplied for use with high-
pressure water systems. It may be fitted with
any of the systems listed to reduce flow rate and
assist economy.
Fit the flow regulator into the outlet fitting as
shown in fig.12.
Asti Bar Mixer Shower
Mixer outlet
Flow regulator
Top
NOTE: The flow regulator must be fitted with
the angled top facing the outlet flow of water.
10
Water flow
Flow regulator
Fig.12
Angled top
section