INSTALLATION
COMMISSIONING THE SHOWER
Attach the appropriate end of the shower
hose to the shower outlet using the
supplied hose washer seal - DO NOT
overtighten. Position the other end of the
shower hose to the bath or tray waste.
DO NOT fit the shower head.
- Turn on the water supply to the shower at the isolating stop valve.
Step
Step
13
- Switch on the electricity supply to the shower at the isolating switch.
- Water will start to flow from the shower hose.
- Allow water to flow for approximately 60 seconds, this will allow the air to
bleed from the installation.
- Isolate the electricity to the shower at the isolating switch. The water will
cease to flow.
- Remove the cover retaining screw and lift off the cover.
Note: The shower will only run water for approximately 90
seconds. If a longer time period is required, isolate the electricity
supply, wait a few seconds and reapply the electricity supply and
water will flow for 90 seconds again.
Step
Step
11
Temporarily fit the cover to the shower.
DO NOT connect the wire from the cover
to shower unit PCB, minor adjustment of
the temperature dial may be necessary to
align with the valve. Secure the cover in
position with one of the retaining screws
20
Step
Step
12
.