On-board help
arrow direction shows the path of the balancing run. In the trial run the imbalance
should change to reduce the residual imbalance.
Tap NEXT to see hint for the trim run.
l
If imbalance reduces, keep the trial weight. If imbalance doubles, remove the trial
weight.
Select necessary weight action for the trim run. The correction screen is shown. In this
l
example, the trial weight has been removed.
Tap NEXT then repeat measure procedure as described above until the imbalance has
l
been reduced or removed. Follow the hints shown on the screen.
110
Shows current balancing step; in this case it is the third
step which is the first trim run (first correction).
The crossed out trial weight shows that the weight has
been removed from the machine.
Shows the recommended mass and angle of the trial
weight after the initial run, with initial weight removed.
No amplitude and phase angle values are shown because
the trim run has not been started.