Fixtures Contained In The Packing; Electrical Connections; Oil Check On Oil-Pressure Power Unit - Fasep RGU600E Instruction Manual

Table of Contents

Advertisement

9.2

Fixtures contained in the packing

The packing case contains also the fixtures box.
Check that all the parts listed are there.
Code
14620010
Clamp
B5119000
Long lever "A"

10.0 ELECTRICAL CONNECTIONS

EVEN THE TINIEST PROCEDU-
RE OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY QUALIFIED STAFF .
BEFORE CONNECTING THE MA-
CHINE MAKE SURE THAT:
• THE MAIN POWER RATING COR-
RESPONDS TO THE MACHINE
RATING AS SHOWN ON THE
MACHINE PLATE;
• ALL MAIN POWER COMPO -
NENTS ARE IN GOOD CONDI-
TION;
• THE ELECTRICAL SYSTEM
I S P R O P E R LY G R O U N D E D
(GROUND WIRE MUST BE THE
SAME CROSS-SECTION AREA
AS THE LARGEST POWER SUP-
PLY CABLES OR GREATER);
• MAKE SURE THAT THE ELEC-
TRICAL SYSTEM FEATURES A
CUTOUT WITH DIFFERENTIAL
PROTECTION SET AT 30 mA.
The machine is supplied with 5 m of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm IEC 309
• 230/400 Volt – 16A
• 3P + Ground
• IP 44
INSTRUCTION, USE
AND MAINTENANCE MANUAL
Description
Only for GG40256D.15, GG40256TD.15,
GG40256.11SL (VARGNAV43AD), GG40256.15SL
(model with inverter version) (VARGNAV43AD)
GG60360D.15 and GG60360TD.15 versions
N.
• Conformity to Norm IEC 309
1
• 230/400 Volt – 32A
1
• 3P + N + Ground
• IP 44
On delivery, the machine is pre-set to operate at a
voltage of 400 V.
For any other type of power supply, ask the manufac-
turer at the time of purchase: a machine functioning
under the required voltage conditions will be prepared.
FIT A TYPE-APPROVED (AS RE-
PORTED BEFORE) PLUG TO THE
MACHINE CABLE (THE GROUND
WIRE IS YELLOW/GREEN AND
MUST NEVER BE CONNECTED TO
ONE OF THE PHASE LEADS).
MAKE SURE THAT THE ELEC-
TRICAL SYSTEM IS COMPATIBLE
WITH THE RATED POWER AB-
SORPTION SPECIFIED IN THIS
MANUAL AND APT TO ENSURE
THAT VOLTAGE DROP UNDER
FULL LOAD WILL NOT EXCEED
4% OF RATED VOLTAGE (10%
UPON START-UP).
IN CASE OF A CHANCE SUPPLY
FAILURE, AND/OR BEFORE ANY
POWER SUPPLY CONNECTIONS,
MOVE THE PEDALS TO THE NEU-
TRAL POSITION.

10.1 Oil check on oil-pressure power unit

T H E O I L - P R E S S U R E P O W E R
UNIT IS DELIVERED WITHOUT
HYDRAULIC OIL, THEREFORE
MAKE SURE THE TANK PROVIDED
IS FILLED WITH OIL WITH VISCO-
SITY DEGREE APPROPRIATE TO
THE AVERAGE TEMPERATURES
IN THE INSTALLATION COUNTRY
AND IN PARTICULAR:
7522-M001-14_P
Page 18 of 168
GG40256.11SL - GG40256.11ST - GG40256.15
GG40256T.15 - GG40256A.15 - GG40256D.15
GG40256TD.15 - GG40256.15SL - GG60360.15
GG60360T.15 - GG60360A.15 - GG60360D.15 - GG60360TD.15
- VISCOSITY 32 (FOR COUNTRIES
WITH ROOM TEMPERATURE
FROM 0 TO 30 DEGREES);
- VISCOSITY 46 (FOR COUNTRIES
WITH ROOM TEMPERATURE
ABOVE 30 DEGREES).
GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gg60360

Table of Contents