8

WebUI

The WebUI is a graphical user interface that a user can use to
interact with the system via a web browser.
The WebUI can be accessed in the browser in the following ways:
1. With a WLAN / Wifi connection to the hotspot in the wall
box, the WebUI can be accessed in the browser at the
following IP address: 172.20.0.1
2. With a WLAN / Wifi or LAN connection to the router, the
WebUI can be accessed in the browser at the following IP
addresses:
– YYYYY (YYYYY --> IP address that has been assigned to
the wall box by the router)
Wallbox IP Address
IP-Address: 172.20.0.1
Login data:
User name: admin
Password: master password (see installation documentation)
IP address e.g.: 172.20.0.1
admin
Master password
8.1

Settings in the WebUI for DLM

The configuration of the DLM in the WebUI will be described
below. For more information see chapter 9, "Dynamic Load
management – Stand-alone mode (DLM)" on page 17.
1. Select the HEMS (Home Energy Management System) tab
in the WebUI.
16
2. Enable expert mode.
3. Under Mode, select "DLM with external meter activated".
4. Under Connection type select "LAN" or "WLAN" (Wifi).
5. Under "Safe current L1" select the maximum possible
current when there is no connection to the smart meter.
NOTE
Set "Safe current" L2 and L3 to 0.
6. Under External Meter IP enter the IP address for the meter
assigned by the router.
7. Under External Meter Module select the meter model.
8. Under External Meter Position select "including wallbox" or
"excluding wallbox".
9. Under Recalculation interval enter 30.
10. Under "Current limit external meter L1" enter the maximum
current.
NOTE
Set "Current limit external meter" L2 and L3 to 0.
HEMS /Smart
Meter
8.2

Setting in the WebUI for HEMS

The configuration of the HEMS in the WebUI will be described
in the following chapter. For more information see chapter 10,
"Home Energy Management System (HEMS)" on page 17.
1. Select the HEMS tab in the WebUI.
2. Enable expert mode.
3. Under Mode select HEMS activated.
4. Under Connection type select LAN or WLAN / Wifi.
5. Under "Safe current L1" select the maximum possible
current when there is no connection to the smart meter.
NOTE
Set "Safe current" L2 and L3 to 0.
6. Under Recalculation interval enter '30'.
7. Under "Current limit external meter L1" enter the maximum
current.
NOTE
Set "Current limit external meter" L2 and L3 to 0.
8. Then apply the settings in the EMS system.