A Troubleshooting The Adc12Dl3200Evm; Table A-1. Troubleshooting - Texas Instruments ADC12DL 00 Series User Manual

Evaluation module
Table of Contents

Advertisement

www.ti.com

A Troubleshooting the ADC12DL3200EVM

Table A-1
lists some troubleshooting procedures.
Issue
General problems
TSW14DL3200EVM LEDs are
not correct
Configuration GUI is not
working properly
Configuration GUI is not able
to connect to the EVM
HSDC Pro software is not
capturing good data or
analysis results are incorrect.
HSDC Pro software gives a
time-out error when capturing
data
Suboptimal measured
performance
SLAU776A – MAY 2018 – REVISED DECEMBER 2023
Submit Document Feedback

Table A-1. Troubleshooting

Verify the test setup shown in
document.
Check power supply to EVM and TSW14DL3200EVM. Verify that the power switch is in the on position.
Check signal and clock connections to EVM.
Visually check the top and bottom sides of the board to verify that nothing looks discolored or damaged.
Make sure the board-to-board FMC connection is secure.
After changing the ADC configuration, click Instrument Options → Download Firmware and download
TSW14DL3200_FIRMWARE.bin.
Power cycle the external power supply to the EVM, and reprogram the LMK and ADC devices.
Verify the installed jumpers on the TSW14DL3200EVM.
Verify that the clock going to the CLK input is connected and the appropriate LEDs are blinking.
Verify that the ADC device internal registers are configured properly.
If LEDs are not blinking, reprogram the ADC EVM devices.
Click Instrument Options → Download Firmware and download TSW14DL3200_FIRMWARE.bin.
Verify that the USB cable is plugged into the EVM and the PC.
Check the computer device manager and verify that a USB serial device is recognized when the EVM is
connected to the PC.
Verify that the green USB Status LED light in the top right corner of the GUI is lit. If it is not lit, click the
Reconnect FTDI button.
Close and start the configuration GUI.
Use the free FT_PROG software from FTDI chip and verify that the onboard FTDI chip is programmed
with the product description ADC12DL3200.
Verify that the TSW14DL3200EVM is properly connected to the PC with a mini USB 3.0 cable and that
the board serial number is properly identified by the HSDC software.
Check that the proper ADC device mode is selected. The mode should match in HSDC Pro and the
ADC GUI.
Check that the analysis parameters are properly configured.
Verify that the ADC sampling rate is correctly set in the HSDC software.
Select Instrument Options → Download Firmware and download TSW14DL3200_FIRMWARE.bin. Try
to capture again.
Click Cal Triggered/Running button two times to calibrate the ADC in the current operating conditions.
The button is located on the Control tab of the configuration GUI.
Check that the spectral analysis parameters are properly configured.
Verify that bandpass filters are used in the clock and input signal paths and that low-noise signal
sources are used.
Copyright © 2023 Texas Instruments Incorporated
Troubleshoot
Figure
3-1, and repeat the setup procedure as described in this
Troubleshooting the ADC12DL3200EVM
ADC12DLXX00 Evaluation Module
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adc12dl3200Adc12dl2500Adc12dl3200evmAdc12dl2500evm

Table of Contents