LOCATION 101 - ACCOUNT CODE FOR PARTITION 6 (6 segments, numerical data)
The account code that is sent when reporting partition 6 is programmed in location 101. If
location 101 is left unprogrammed (all "10") then the account code corresponding to the
phone number that is dialled will be used. If the account code is less than six digits, program a
"10" in the segment immediately after the last digit of the account code. If the account code is
6 digits long, program all 6 segments.
LOCATION 102 - PARTITION 6 FEATURE AND REPORTING SELECTIONS (5 segments, feature selection data)
Location 102 is used to enable certain features that the user can access or see from the
keypad of the system. In addition, certain communicator reports are enabled in this location.
Each of these features can be enabled by partition. This location contains 5 segments, with
eight possible features per segment. Refer to location 23 for the feature selections. If all the
segments are blank (nothing enabled), the features for partition 1 will be used.
LOCATION 103 - PARTITION 6 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 103 is used to enter the entry and exit times in seconds. There are 2 separate entry
and exit times. Valid entries are 10-255 seconds. If all the segments are "0", the entry and exit
times for partition 1 will be used.
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
LOCATION 104 - ACCOUNT CODE FOR PARTITION 7 (6 segments, numerical data)
The account code that is sent when reporting partition 7 is programmed in location 104. If
location 104 is left unprogrammed (all "10") then the account code corresponding to the
phone number that is dialled will be used. If the account code is less than six digits, program a
"10" in the segment immediately after the last digit of the account code. If the account code is
6 digits long, program all 6 segments.
LOCATION 105 - PARTITION 7 FEATURE AND REPORTING SELECTIONS (5 segments, feature selection data)
Location 105 is used to enable certain features that the user can access or see from the
keypad of the system. In addition, certain communicator reports are enabled in this location.
Each of these features can be enabled by partition. This location contains 5 segments, with
eight possible features per segment. Refer to location 23 for the feature selections. If all the
segments are blank (nothing enabled), the features for partition 1 will be used.
NX-8-EUR Installation manual
Entry time 1
Entry time that will be used when a delay 1 zone type
initiates an entry delay
Exit time 1
Exit time that will be used for all zones designated as
delay 1
Entry time 2
Entry time that will be used when a delay 2 zone type
initiates an entry delay
Exit time 2
Exit time that will be used for all zones designated as
delay 2
Reserved
Reserved