LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
NX-8-EUR Installation manual
1 =
On: Disables auto-bypassing of force armable zones at the end of the
exit delay
2 =
Reserved
3 =
Reserved
4 =
Reserved
5 =
Reserved
6 =
Reserved
7 =
Reserved
8 =
Reserved
Entry time 1
This is the entry time that will be used when a delay 1
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Exit time 1
This is the exit time that will be used for all zones
designated as delay 1.
Valid entries are 10-255 seconds.
Entry time 2
This is the entry time that will be used when a delay 2
zone type initiates an entry delay.
Valid entries are 10-255 seconds.
Exit time 2
This is the exit time that will be used for all zones
designated as delay 2.
Valid entries are 10-255 seconds.