This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall
not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without
Page 1
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without...
Table of Contents 1. Introduction ................2 2. Appearance ................. 3 3. Features ..................3 4. Set up Instructions ..............4 5. Data Report ................5 5.1 Example of ReportDataCmd ..........5 5.2 Example of ConfigureCmd ..........7 5.3 Example for MinTime/MaxTime logic ........ 9 6.
1. Introduction R718J2 is a ClassA external 2-way dry contact device based on LoRaWAN open protocol of Netvox. It can externally connect various switches, buttons, relays and reed switch output. It can detect the closing or disconnecting signal of dry contact and is compatible with LoRaWAN protocol.
2. Appearance Dry Contact 1 Indicator Function Key Dry Contact 2 3. Features ⚫ SX1276 wireless communication module ⚫ 2 ER14505 lithium batteries (3.6V / section) parallel power supply ⚫ Dry contact detection ⚫ Magnetic base ⚫ IP65 ⚫ Compatible with LoRaWAN Class A ⚫...
4. Set up Instructions On/Off Power on Insert batteries. (Users may need a screwdriver to open the battery cover.) Turn on Press and hold the function key for 3 seconds until the green indicator flashes once. Turn off (Factory resetting) Press and hold the function key for 5 seconds until the green indicator flashes 20 times.
Note: a. The device reports data depending on the burning configuration. b. The interval between two reports must be the minimum interval. c. Please check the Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://cmddoc.netvoxcloud.com/cmddoc to resolve uplink data.
Page 7
0: off 1: on) 0: off 1: on) Example of Uplink: 0143019F00000000000000 byte (01): Version byte (43): DeviceType 0x43 - R718J2 byte (01): ReportType byte (9F): Battery-3.1V , 9F (HEX) = 31 (DEC), 31* 0.1V = 3.1V byte (00): Status-off byte (00): Status-off...
Page 9
Device Description Device NetvoxPayLoadData CmdID Type SetLastMessage Resendtime (1 byte) Unit:1s, Range: 3-254s Reserved 0x1F ResendtimeReq when 0 or 255 no resend, default is no resend (8 bytes, Fixed 0x00) SetLastMessage Status Reserved 0x9F All (0xFF) ResendtimeRsp (0x00_success) (8 bytes, Fixed 0x00) only used in 0xFF GetLastMessage...
5.3 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime sleeping (MinTime) sleeping (MinTime) Wakes up and collect data Wakes up and collect data Wake up and collect data REPORTS 3.6V REPORTS 3.6V REPORTS 3.6V...
Page 11
Notes: 1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data. 2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the device reports according to MinTime interval.
State monitoring of doors and windows in home or business The occasion is necessary to judge the state of the sensor through the dry contact signal. A diagram that the dry contact sensor (R718J2) connecting to two wired smoke sensors. DC24V+ External power supply...
7. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
8. Important Maintenance Instruction Kindly pay attention to the following to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.
Need help?
Do you have a question about the R718J2 and is the answer not in the manual?
Questions and answers