netvox R718J User Manual page 8

Wireless dry contact interface
Hide thumbs Also See for R718J:
Table of Contents

Advertisement

(1) Configure device parameters
MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v
Downlink: 0121003C003C0100000000
Device returns:
8121000000000000000000 (configuration is successful)
8121010000000000000000 (configuration failed)
(2) Read device parameters
Downlink: 0221000000000000000000
Device returns:
8221003C003C0100000000 (current device parameters)
SetLastMessage
ResendtimeReq
SetLastMessage
ALL(0xFF)
ResendtimeRsp
only used in
contact switch
GetLastMessage
ResendtimeReq
device type
GetLastMessage
ResendtimeRsp
Set resend time =5s
Downlink:1FFF050000000000000000
Response:
9FFF000000000000000000(Configuration success)
9FFF010000000000000000(Configuration failure)
*The function of Resendtime is supported by the firmware version after 2020/05/13 version
003C(H
= 60(D
ex)
0x1F
when 0 or 255 no resend, default is no resend
0x9F
0xFF
0x1E
0x9E
when 0 or 255 no resend,default is no resend
ec)
Resendtime(1Byte)
Unit:1s , Range:3-254s
Status
(0x00_success)
Reserved
(9Bytes,Fixed 0x00)
Resendtime(1Byte)
Unit:1s , Range:3-254s
7
Reserved
(8Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)