Example 1 of Uplink: 0121012401000000000000
st
1
byte (01): Version
2
nd
byte (21): DeviceType 0x21 - R718J
3
rd
byte (01): ReportType
th
4
byte (24): Battery-3.6v , 24(HEX)=36(DEC),36*0.1v=3.6v
th
5
byte (01): Status-on
th
th
6
~ 11
byte (000000000000): Reserved
Example 2 of Uplink: 0121019F00000000000000
st
1
byte (01): Version
2
nd
byte (21): DeviceType 0x21 - R718J
3
rd
byte (01): ReportType
th
4
byte (9F): Battery-3.1v , 1F (HEX)=31(DEC),31*0.1v=3.1v
// The bit 7=0 represent normal battery voltage, bit 7=1 represent low battery
th
5
byte (00): Status-off
th
th
6
~ 11
byte (000000000000): Reserved

5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
Config
ReportReq
Config
ReportRsp
R718J
ReadConfig
ReportReq
ReadConfig
ReportRsp
1
DeviceType
CmdID
DeviceType
0x01
(2bytes Unit:s)
0x81
0x21
0x02
0x82
(2bytes Unit:s)
Var (Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MinTime
MaxTime
(2bytes Unit:s)
Status
(0x00_success)
(9Bytes,Fixed 0x00)
MinTime
MaxTime
(2bytes Unit:s)
6
BatteryChange
(1byte Unit:0.1v)
(4Bytes,Fixed 0x00)
Reserved
(8Bytes,Fixed 0x00)
Reserved
BatteryChange
(1byte Unit:0.1v)
(4Bytes,Fixed 0x00)
Reserved
Reserved

Advertisement