CAMERA ADJUSTMENT

1. Access the cameras by removing the dome. Loosen the locking
screws on the lip of the dome. DO NOT TAKE THESE SCREWS
OUT. Once the screws are loosened, turn the dome counter
clockwise until it stops, then pull the dome off.
CAMERA FOCUSING (FOR EACH CAMERA)
Fixed Lens: Loosen the set screw in the lens mount. Manually
rotate the lens until a clear picture is achieved. Once
the focus is set, retighten the set screw (Figure 5).
Fixed lens
Figure 5
Auto Iris Lens:
NOTE: THE AUTO IRIS LENS IS SET AT THE FACTORY.
• IF YOU EXPERIENCE VIDEO TOO LIGHT OR DARK
AUTO IRIS ADJUSTMENT MAY BE NEEDED.
SEE THE TROUBLESHOOTING SECTION FOR
ADJUSTMENT INFORMATION.

CAMERA SETTINGS

NOTE: To determine which camera is used in your unit, locate the
serial number on the inside of the housing. Match the two
letter prefix with the corresponding instructions included
here for adjustments.
HIGH-RES BLACK & WHITE
FIXED AND FIXED VARI-FOCAL LENSES. There are no user
adjustable settings on these units (Figure 7).
Set screw
Figure 7
AUTO IRIS LENSES. The dip switches are factory set with AES
off and backlight compensation on (Figure 8). The auto iris is also
set at the factory, but an adjustment screw is included for use if
needed. See page 10 for instructions on adjusting Auto Iris.
Backlight
Compensation
Default On
Figure 8
-  -
BW Fixed and Vari-Focal
BW Auto Iris
AES Default Off
Auto Iris
adjustment
screw