Gossen MetraWatt PROFITEST H+E EXPERT CHECK Operating Instructions Manual
Gossen MetraWatt PROFITEST H+E EXPERT CHECK Operating Instructions Manual

Gossen MetraWatt PROFITEST H+E EXPERT CHECK Operating Instructions Manual

Test instrument and function tester for ac charging stations per iec 61851-1, vde 0122-1

Advertisement

Quick Links

Operating Instructions
PROFITEST H+E EXPERT CHECK
Test Instrument and Function Tester for AC Charging
3-447-180-03
Stations per IEC 61851-1, VDE 0122-1
1/9.23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFITEST H+E EXPERT CHECK and is the answer not in the manual?

Questions and answers

Summary of Contents for Gossen MetraWatt PROFITEST H+E EXPERT CHECK

  • Page 1 Operating Instructions PROFITEST H+E EXPERT CHECK Test Instrument and Function Tester for AC Charging 3-447-180-03 Stations per IEC 61851-1, VDE 0122-1 1/9.23...
  • Page 2: Table Of Contents

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Table of Contents Safety Instructions ...............1 1.1 General ..................... 1 1.2 Personnel Qualifications ................1 1.3 Handling the Tester ................... 1 1.4 Damaged Tester ..................2 Applications................3 2.1 Intended Use / Use for Intended Purpose..........3 2.2 Use for Other than Intended Purpose ............
  • Page 3 Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK 9.3 Performing Tests and Inspections ............16 9.4 Switching the Tester Off ................19 Registering the Tester............20 Maintenance ...............20 11.1 Cleaning....................20 11.2 Fuse......................20 Contact, Support and Service ...........22 CE Declaration..............23 Returns and Environmentally Sound Disposal ....24...
  • Page 4: Safety Instructions

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Safety Instructions General • Carefully and completely read and adhere to these operating instructions. The documents can be found at http://www.gossenmetrawatt.com. Retain these documents for future reference. • Carefully and completely read and adhere to the product documentation for the tested/inspected AC charging point.
  • Page 5: Damaged Tester

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK • Do not use the tester and its accessories after extraordinary stressing due to transport. • Do not expose the tester to direct sunlight. • The tester may only be used as long as the fuses are in flawless condition.
  • Page 6: Applications

    Please read this important information! Intended Use / Use for Intended Purpose The PROFITEST H+E EXPERT CHECK is a tester for checking AC charging points in accordance with DIN EN/IEC 61851-1 (VDE 0122-1). The tester can be used to check the performance of AC charging points. In combination with measuring/test instruments from the PROFITEST MF or PROFITEST MASTER IQ series, the effec- tiveness of protective measures can be tested at AC charging points.
  • Page 7: Documentation

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK Documentation Identifiers The following identifiers are used in this documentation: Identifier Meaning Safety information that must be complied with Attention! Warning Important information which must be taken into consid- Note! eration and complied with Important ...
  • Page 8: Getting Started

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Getting Started 1. Read and adhere to the product documentation. In particular, observe all safety information in the documentation, on the tester and on the packaging.  “Safety Instructions” 1  “Applications” 3 ...
  • Page 9: Background Knowledge Concerning Electromobility

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK Background Knowledge Concerning Electromobility Charging Point / Wallbox Electric vehicles are charged with alternating current (AC) at AC charging points in charging mode 3 with type 2 plug. Since electric vehicle batteries can only store direct current (DC), the alternating current is converted to direct current by the elec- tric vehicle’s on-board charger.
  • Page 10 PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Figure 2: Type 2 Plug Layout Function Function Phase conductors Neutral conductor Protective conductor Proximity plug Signal line for detecting the current carrying capacity of the cable Control pilot Pilot line for safety testing and communication...
  • Page 11: The Tester

    – Testing of residual current circuit breakers (RCD/R) – Sensor testing, 6 mA RDC-DD/RCMB – Fault loop impedance (loop resistance), internal system resistance Scope of Delivery Please check for completeness. PROFITEST H+E EXPERT CHECK (M525R) Charging cable (micro USB plug) Operating instructions (this document)
  • Page 12: Device Overview

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Device Overview 6.4.1 Front Measuring Measuring Inputs Inputs (on top) (on the side) Fuse (on the side) CP Socket (on the side) Display Type 2 Rotary Switch, Plug CP STATE Rotary Switch, PP STATE...
  • Page 13: Relevant Standards

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK Relevant Standards The tester has been manufactured in accordance with the following safety regula- tions: IEC 61010-1 Safety requirements for electrical equipment for measure- EN 61010-1 ment, control and laboratory use – general requirements...
  • Page 14: Technical Data

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Technical Data Earthing contact socket Max. 10 A, 230 V Fuse: T 10 A, 250 V, 20 × 5 mm Measuring Measuring inputs 4 mm Connections L1, L2, L3, N, PE CP signal output ±...
  • Page 15 Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK 6.6.1 Test/Analysis Standards DIN EN IEC 61851-1 VDE 0122-1 Electric vehicle conductive charging system – Part 1: General requirements Measurement of voltage values in all three phases and N 6.6.2 Test Parameters no cable connected (∞ Ω) 13 A 13 A cable (1.5 kΩ)
  • Page 16: User Interface

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH User Interface The tester is equipped with a membrane keypad including function keys and a rotary switches. The screen is used to display measurement results. The rotary switches can be used to select the test and adjust the test parameters.
  • Page 17: Initial Startup

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK Control Description Element PP STATE Cable simulation: N.C. no cable connected (∞ Ω) 13 A 13 A cable (1.5 kΩ) 20 A 20 A cable (680 Ω) 32 A 32 A cable (220 Ω) 63 A 63 A cable (100 Ω)
  • Page 18: Power Supply

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Power Supply The tester is powered by an internal rechargeable battery. The internal battery is charged via the tester’s USB port. Battery Charge Level The battery charge level is displayed briefly after switching the tester on. If the bat- tery charge level drops to below a certain value during operation, a message is dis- played at the screen.
  • Page 19: Operation

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK Operation The tester performs functional testing of AC charging points. AC charging points in charging mode 3 with a type 2 socket or a permanently attached type 2 cable can be tested. The results appear at the display in plain text.
  • Page 20 PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH Testing includes visual inspection, measurement, and testing. Documentation of testing is also required. The tester facilitates the measuring and testing steps to this end. The respective tests must be performed and their parameters must be set independently by the operator.
  • Page 21 1. Connect the oscilloscope to the PROFITEST H+E EXPERT CHECK: connect the CP socket to the oscilloscope’s measuring terminal and the PE socket to the oscilloscope’s ground terminal. 2. Connect the plug from the PROFITEST H+E EXPERT CHECK to the charging point. 3. Authorize yourself at the AC charging point.
  • Page 22: Switching The Tester Off

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH 4. Perform electrical testing in accordance with the operating instructions of the measuring/test instrument.  The protective measure is tested. Expected result: in accordance with the specification stipulated in the standard. Switching the Tester Off 1.
  • Page 23: Registering The Tester

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK 10 Registering the Tester You can register your tester in your personal myGMC account. 1. Access the website at https://www.gmc-instruments.de/services/mygmc/. 2. Create a personal myGMC account. 3. Register your tester in your personal myGMC account.
  • Page 24 PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH 1. Open the tester’s fuse compartment. Use the slotted screwdriver to this end and turn the fuse holder counterclockwise until it’s unlocked and can be removed. 2. Remove the defective fuse. 3. Insert the new fuse.
  • Page 25: Contact, Support And Service

    PROFITEST H+E EXPERT CHECK 12 Contact, Support and Service Gossen Metrawatt GmbH can be reached directly and simply – we have a single number for everything! Whether you require support or training, or have an individ- ual inquiry, we can answer all of your questions here: Monday to Thursday: 8 a.m.
  • Page 26: Ce Declaration

    PROFITEST H+E EXPERT CHECK Gossen Metrawatt GmbH 13 CE Declaration The tester fulfills all requirements of applicable EU directives and national regula- tions. We confirm this with the CE mark. The CE declaration is available upon request.
  • Page 27: Returns And Environmentally Sound Disposal

    Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK 14 Returns and Environmentally Sound Disposal This tester is subject to directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) and its German national equivalent implemented as the Waste Electrical and Electronic Equipment Act (ElektroG) on the marketing, return and environmentally sound disposal of electrical and electronic equipment.
  • Page 28 Gossen Metrawatt GmbH PROFITEST H+E EXPERT CHECK © Gossen Metrawatt GmbH Prepared in Germany • Subject to change, errors excepted • PDF version available on the Internet All trademarks, registered trademarks, logos, product names and company names are the property of their respective owners.