Tm4411 Temperature Sensor Installation; Juvmpauto Electric Wiper Driver (Optional) Installation - Jandy JUVMP120 Installation And Operation Manual

Uv medium pressure
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
1.
Radiation sensor input "UV-C" at the
UV reactor
2.
UVX-SE radiation sensor
3.
UVX-05 cable
Figure 8.
Radiation Sensor Connections
Connect the UVX-SE sensor with the EVC059 cable
supplied with the unit to the corresponding terminals
at the terminal block inside the control box.
3.9
TM4411 Temperature Sensor Installation
The TM4411 temperature probe consists of a Pt-100
sensor that converts its response in a 4/20 mA
analog signal. The TM4411 sensor comes factory
calibrated so that it is not necessary to make any
process for recalibration at installation time.
Page 14
Jandy
UV Medium Pressure | Installation & Operation Manual
®
1.
Temperature sensor input "Temp" at the UV
2.
TM4411 temperature sensor
3.
EVC005 cable
Figure 9.
Temperature Sensor Connections
Screw the TM4411 sensor on the position labeled as
"TEMP" at the body of the UV reactor.
Connect the TM4411 sensor with the EVC005 cable
supplied with the unit to the corresponding terminals
at the terminal block inside the control box.
3.10 JUVMPAUTO Electric Wiper Driver
(Optional) Installation
Jandy UV MP systems may be equipped with
automatic cleaning system of the quartz sleeve,
have a rotary electric driver that activates the wiper
mechanism at programmable time intervals in the
control panel of the unit. The JUVMPAUTO driver
has an IP-54 plastic enclosure. All the engine and
gearbox bearings are permanently lubricated.
The JUVMPAUTO driver has a mechanism that also
allows to drive the wiper manually.
The JUVMPAUTO driver is supplied fully assembled
from factory so it is not necessary to perform any
operation on it.