FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed
where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions
in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices
and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which may cause serious injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information about the installation, operation and safe use of this product. This information should be given
to the owner/operator of this equipment.
Installation and Operation Manual
Manuel d'installation et d'utilisation
Manual de instalación y operación
WARNING

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Jandy JSWC40

  • Page 1 Manual de instalación y operación Commercial Salt Chlorinator Models: JSWC40, JSWC53, JSWC80, JSWC100 WARNING FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 2: Table Of Contents

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Table of Contents 4.3 Determining Pool Size (Gallons of Water in Your Section 1. Important Safety Instructions ..3 Pool) ............. 21 1.1 Safety Instructions ......... 3 4.4 Selecting Model Size ........21 Section 2.
  • Page 3: Section 1. Important Safety Instructions

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
  • Page 4 ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® WARNING Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body.
  • Page 5 Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® CAUTION It is important to note that certain materials used in and around swimming pools and spas may not be compatible with chemicals commonly used to purify pool and spa water (e.g. acids, chlorine, salt, stabilizers, etc.).
  • Page 6: Section 2. System Description

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Section 2. System Description Figure 1. Typical Installation Pump Pool Intake Pool Returns Cell Control Center Swimming Pool Board Filter Other Devices (Heater, etc.) Flowswitch ATTENTION INSTALLER: Various application notes (including more detailed instructions) are available from the Dealer covering installation, operation, maintenance, and plumbing of the chlorinator system.
  • Page 7: Product Description

    65 gpm 88 gpm 88 gpm Number of electrodes Material Polypropylene Connection flanges 2” x 2 1/2” Jandy unions Rate pressure 50 PSI Working temperature 59°F – 104°F max. DIMENSIONS / WEIGHT 14.6" W x 24.92" H x 8.9" Ø / 14.6"...
  • Page 8: Electrical Specifications

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Electrical Specifications Control Center Specification JSWC40 JSWC53 JSWC80 JSWC100 POWER SUPPLY Power rating 120 – 240VAC 50/60Hz 1 phase Consumption 3.2 - 1.7 A 3.9 – 2.0 A 6.5 – 3.3 A 7.1 –...
  • Page 9: Control Panel Description

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Control Panel Description Salt Electrolysis System Advanced Water Treatment Figure 2. Control Panel Production indicator (%) External chlorine control indicator (enabled / disabled) Salt alarm indicator (high / low)
  • Page 10: Section 3. Installation Instructions

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Section 3. Installation Instructions WARNING When using electrical products, basic precautions should always be followed, including the following: • RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit breaker.
  • Page 11: Installing Control/Power Centers

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Flow direction marked in the cell must be WARNING respected. Recirculation system must guarantee the minimum flow stated in the Technical A pressure switch or mechanical flow detector palette is Specifications Table.
  • Page 12 ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® JSWC. 80/100 JSWC. 40/53 Output Input Power +24V 110-240VAC 10A Pool cover Flowswitch External chlorine control Cell connection Input 110-240VAC Fuse ON/OFF switch Cell output 1 Cell output 2 10.
  • Page 13: Terminal Block (External Signals) Description

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Terminal Block (External Signals) Polarity Switching Configuration Description The polarity switching frequency is configuring using jumpers located at HMI on the backside of In addition to the basic operations, the electrolysis powerpack front panel.
  • Page 14: System Configuration / Configuration Menu

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® System Configuration / Configuration Menu Press the down “V” button to visualize system parameters. 10 secs Pool Cover Model & Polarity Frequency Auxiliary Electrode (gas) Sensor flow cell Total Time (hours)
  • Page 15: Pool Cover Control

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Pool Cover Control 3.8.1 Enabling / Disabling Cover Control The system has a dry contact input to adapt system chlorine production in case the pool cover is deployed. When the contact connected to this input...
  • Page 16: Flow Detector (Built-In)

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Flow Detector (Built-In) Gas detector: If a permanent air or gas bubble is generated at the top of the electrolysis cell the auxiliary electrode (built-in flow sensor) will not be in contact with the water a FLOW ALARM will be appear.
  • Page 17: 3.10 External Chlorine Control

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® FLOWSWITCH Enabled = flowswitch enabled (default) Disabled = flowswitch disabled 3.10 External Chlorine Control This input can be used to control system with a dry- contact with an external ORP/chlorine controller. This function can be enabled or disabled.
  • Page 18: Information About The Model And Polarity

    External ring down “V” button. “Stop” indicator will appear in Model of the device the HMI. Jandy 40: 20+40 on Jandy 53: 20+40+60 on • Keep “V” button pressed for 10 seconds. Jandy 80: 20+40+60+80 on • Push “V” button 4 times to see model and polarity Jandy 100: 20+40+60+80+100 on switching frequency.
  • Page 19: 3.13 Firmware Version

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® 3.13 Firmware Version • Decrease the production rate to 0% with the down “V” button. “Stop” indicator will appear in the HMI. • Keep “V” button pressed for 10 seconds.
  • Page 20 ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Section 4. New Installation Pool Water Preparation ATTENTION INSTALLER: Various application notes (including more detailed instructions) are available from the Dealer covering installation, operation, maintenance, and plumbing of the chlorinator system.
  • Page 21: Section 4. New Installation

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® – Pump and filter runtime. Sanitizer is only Selecting Model Size introduced when the pump is running and water When sizing a chlorinator system for a pool or spa,...
  • Page 22: Optimum Pool Water Conditions

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® – Chloramines should not be present in pool Optimum Pool Water Conditions water. When organic materials combine with In accordance with Association of Pool and Spa free chlorine, chloramines are formed. This...
  • Page 23: Salt (Nacl Sodium Chloride)

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® • Avoid using salt with anti-caking agents (sodium CAUTION ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some It is important to note that certain materials used in and around...
  • Page 24 ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. To avoid clogging the filter or damaging power center and pump, do not add salt through either the skimmer, main drain, or surge tank.
  • Page 25: Section 5. Operating Instructions

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Section 5. Operating Instructions Device Start-Up Production Setpoint Value Flowchart for changing the operating parameters with the system menu Page 25...
  • Page 26 ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Display Table LED ON LED BLINKING COVER ENABLED LED COVER ON HIGH SALT ACTIVATED COVER LED SALT ON LED COVER ON Production 20% blinking, setpoint 20% LOW SALT LED SALT BLINKING...
  • Page 27: Alarms

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® STOP CL EXT FLOW SWITCH ENABLED SET & PROD 0% LEDS FLOW ON LED STOP & CL EXT blinking FLOW SWITCH ALARM FLOW CELL ENABLED LEDS FLOW & STOP BLINKING LEDS FLOW &...
  • Page 28: Operation

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® Operation 5.6.2 Apply Power Check that the filter is 100% clean, and ensure CAUTION that the swimming pool and the installation do not contain copper, iron or algae. Ensure that...
  • Page 29: Section 6. User Maintenance Instructions

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® 5.6.3 Recommendations Section 6. User Maintenance Instructions DO List – Read and keep your manual in a safe place. The following information describes how to care for your sanitizing system.
  • Page 30: Electrolytic Cell Cleaning - As Needed

    ENGLISH Jandy Commercial Salt Chlorinator | Installation & Operation Manual ® • Stabilizer (Cyanuric Acid). Test pool water Use a high pressure jet of water from a garden stabilizer (cyanuric acid) level using a test hose. If the cell cannot be reasonably cleaned in kit or by having a water sample tested by a this manner, acid cleaning is necessary.
  • Page 31: Winterizing

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Winterizing Very little chlorine is needed in cold water. Below 51°F (11°C), operating the chlorinator in cold water might result in over-chlorinated pool water. If preventative measures are not taken, freezing water may cause severe damage to the cell and flow/ temp/salinity sensor.
  • Page 32: Section 7. Troubleshooting

    - Check the chemical parameters into the water (pH, combined chlorine, The chlorine level into the water is isocyanuric acid) are correct very low - Increase filtration time - Add chlorine stabilizer (isocyanuric acid) until reach 50-75 ppm If issues persist, contact Jandy Technical Support at 1.800.822.7933 Page 32...
  • Page 33: Section 8. Exploded Views And Replacement Kits

    Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® Section 8. Exploded Views and Replacement Kits Page 33...
  • Page 34 ® RKIT CODE DESCRIPTION R0976300 Screw Kit R0976400 Flow Sensor R0976500 Main Body Gasket R0976600 Electrode Kit JSWC40 R0976700 Electrode Kit JSWC53 R0976800 Electrode Kit JSWC80 R0976900 Electrode Kit JSWC100 R0977000 Electrode Support Kit 75/100 R0977100 Electrode Support Kit 150/190...
  • Page 35 Jandy Commercial Salt Chlorinator | Installation & Operation Manual ENGLISH ® NOTES Page 35...
  • Page 36 Zodiac Pool Systems LLC 2882 Whiptail Loop # 100 Carlsbad, CA 92010, USA Jandy.com | 1.800.822.7933 Zodiac Pool Systems Canada, Inc. 2-3365 Mainway Burlington, ON L7M 1A6, Canada Jandy.ca | 1.800.822.7933 ® ©2022 Zodiac Pool Systems LLC. All rights reserved. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license.
  • Page 37 Manual de instalación y operación Clorador de sal comercial Modelos: JSWC40, JSWC53, JSWC80, JSWC100 ADVERTENCIA PARA SU SEGURIDAD: La instalación y el servicio técnico de este producto deben estar a cargo de un contratista cualificado y matriculado para trabajar con equipamientos para piscinas en la jurisdicción en la que se instalará...
  • Page 38 ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Contenido Sección 1. Instrucciones importantes de 4.2 Determinación del tamaño de la piscina seguridad ........39 (litros de agua en la piscina) ......56 1.1 Instrucciones de seguridad ......39 4.3 Determinación del tamaño de la piscina...
  • Page 39: Sección 1. Instrucciones Importantes De Seguridad

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Sección 1. Instrucciones importantes de seguridad LEA Y SIGA TODAS LAS INSTRUCCIONES Instrucciones de seguridad Todos los trabajos de electricidad deben ser realizados por un electricista matriculado y adherir a todas las normativas nacionales, estatales y locales.
  • Page 40 ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® ADVERTENCIA La inmersión prolongada en agua caliente puede causar hipertermia. La hipertermia se produce cuando la temperatura corporal interna supera por varios grados la temperatura corporal normal de 98,6 °F (37 °C). Algunos de los síntomas de hipertermia incluyen mareo, desvanecimiento, somnolencia, pereza y un aumento de la temperatura corporal interna.
  • Page 41 Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® PRECAUCIÓN Es importante señalar que determinados materiales utilizados en las piscinas y los hidromasajes y en torno a ellos tal vez no sean compatibles con los productos químicos que se utilizan comúnmente para purificar el agua de la piscina y del hidromasaje (por ejemplo, ácidos, cloro, sal, estabilizadores, etc.).
  • Page 42: Sección 2. Descripción Del Sistema

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Sección 2. Descripción del sistema Figura 1. Instalación típica Bomba Admisión de la piscina Retornos a la piscina Celda Centro de control Placa de la piscina Filtro Otros dispositivos (calentador, etc.)
  • Page 43: Descripción Del Producto

    65 gpm 88 gpm 88 gpm Cantidad de electrodos Material Polipropileno Bridas de conexión Uniones Jandy de 2” x 2 1/2” Presión nominal 50 PSI Temperatura de trabajo 59 °F – 104 °F máx. DIMENSIONES/PESO 14.6" ancho x 24,92" alto x 14,6"...
  • Page 44: Especificaciones Eléctricas

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Especificaciones eléctricas Centro de control Especificación JSWC40 JSWC53 JSWC80 JSWC100 FUENTE DE ALIMENTACIÓN Clasificación nominal de 120 – 240 VCA 50/60 Hz monofásica energía Consumo 3,2 - 1,7 A 3,9 –...
  • Page 45: Descripción Del Panel De Control

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Descripción del panel de control Sistema de electrólisis con sal Tratamiento avanzado del agua Figura 2. Panel de control Indicador de producción (%) Indicador de control de cloro externo (habilitado/inhabilitado) Indicador de alarma de la sal (alta/baja) Indicador de modo de configuración...
  • Page 46: Sección 3. Instrucciones De Instalación

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Sección 3. Instrucciones de instalación ADVERTENCIA Al utilizar productos eléctricos, siempre se deben seguir precauciones básicas, incluidas las siguientes: • RIESGO DE DESCARGA ELÉCTRICA QUE PUEDE RESULTAR EN LESIONES GRAVES O LA MUERTE.
  • Page 47: Instalación De Los Centros De Control/Energía

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Debe respetarse la dirección del flujo marcada ADVERTENCIA en la celda. El sistema de recirculación debe garantizar el flujo mínimo indicado en la tabla de Con la unidad se suministran además un interruptor de presión o una especificaciones técnicas.
  • Page 48 ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® JSWC. 80/100 JSWC. 40/53 Salida Energía de entrada 110-240 VCA 10 A +24 V 30 A Cubierta para la piscina Interruptor de flujo Control de cloro externo Conexión de la celda...
  • Page 49: Descripción Del Bloque De Terminales (Señales Externas)

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Descripción del bloque de terminales Configuración de la conmutación de (señales externas) polaridad Además de las operaciones básicas, el sistema de La frecuencia de conmutación de polaridad se configura electrólisis tiene diversas señales de entrada-salida,...
  • Page 50: Configuración Del Sistema/Menú De Configuración

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Configuración del sistema/menú de configuración Presione el botón “V” hacia abajo para visualizar los parámetros del sistema. 10 s Cubierta para la piscina Modelo y frecuencia de...
  • Page 51: Control De La Cubierta De La Piscina

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Control de la cubierta de la piscina 3.8.1 Habilitar/inhabilitar el control de la cubierta El sistema tiene una entrada de contacto sin energía para adaptar la producción de cloro del sistema en caso de que se despliegue la cubierta de la piscina.
  • Page 52: Detector De Flujo (Incorporado)

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Detector de flujo (incorporado) Dectector de gas: Si se genera una burbuja de aire o gas permanente en la parte superior de la celda de electrólisis, el electrodo auxiliar (sensor de flujo incorporado) no estará...
  • Page 53: 3.10 Control De Cloro Externo

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® INTERRUPTOR DE FLUJO Habilitado = Interruptor de flujo habilitado (predeterminado) Inhabilitado = Interruptor de flujo inhabilitado 3.10 Control de cloro externo Esta entrada puede utilizarse para controlar el sistema con un contacto sin energía con un controlador de...
  • Page 54: Información Sobre El Modelo Y La Frecuencia De Conmutación De Polaridad

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® 3.11 Información sobre el modelo y la frecuencia de conmutación de polaridad Anillo interno Tiempo de inversión de la polaridad 2 h/2 h: 20 encendido 3 h/3 h: 20+40 encendido...
  • Page 55: 3.13 Versión Del Firmware

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® 3.13 Versión del firmware • Reduzca la tasa de producción a 0 % con el botón “V” hacia abajo. Aparecerá el indicador “Stop” (Parada) en la HMI. • Mantenga presionado el botón “V” durante 10 segundos.
  • Page 56: Sección 4. Nueva Instalación

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Sección 4. Nueva instalación Preparación del agua de la piscina ATENCIÓN INSTALADOR: Hay distintas notas de aplicación (que incluyen instrucciones más detalladas) disponibles con el distribuidor. Tratan la instalación, la operación, el mantenimiento y las tuberías del sistema clorador.
  • Page 57: Selección Del Tamaño Del Modelo

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® – Dilución de los productos químicos debido a Selección del tamaño del modelo las lluvias, el retrolavado, etc. La pérdida de Al establecer el tamaño de un sistema clorador para agua que contiene sanitizante también provoca...
  • Page 58: Condiciones Óptimas Del Agua De La Piscina

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® – Los metales (algunos) pueden provocar la profesional en piscinas analice el agua y que pérdida de cloro. Además, los metales pueden se equilibre adecuadamente antes de activar el teñir la piscina.
  • Page 59: Sal (Nacl, Cloruro De Sodio)

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Tome muestras para el análisis: 4.8.2 Qué tipo de sal utilizar • Cuanto más pura sea la sal, mayores serán la vida En la línea de retorno de la piscina.
  • Page 60 ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® 4.8.4 Cómo agregar sal a la piscina Encienda la bomba para hacer circular el agua de la piscina. IMPORTANTE: Apague la producción de cloro. Para ello, presione el botón con la flecha A y establezca la tasa de PRODUCCIÓN DE CLORO...
  • Page 61: Sección 5. Instrucciones Operativas

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Sección 5. Instrucciones operativas Puesta en funcionamiento del dispositivo Valor del punto de ajuste de producción Diagrama de flujo para cambiar los parámetros operativos con el menú del sistema...
  • Page 62: Tabla De La Pantalla

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Tabla de la pantalla LED ENCENDIDO LED PARPADEANTE CUBIERTA HABILITADA LED DE CUBIERTA ENCENDIDO SAL ALTA CUBIERTA ACTIVADA LED DE SAL ENCENDIDO LED DE CUBIERTA ENCENDIDO Producción 20 % parpadeante, punto de ajuste 20 %...
  • Page 63: Alarmas

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® DETENER CONTR. EXT. INTERRUPTOR DE FLUJO HABILITADO ESTAB. Y PROD. 0 % LED DE FLUJO ENCENDIDO LED DE PARADA Y CONTR. EXT. parpadeante ALARMA DEL INTERRUPTOR DE FLUJO...
  • Page 64: Operación

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® Operación a 5 - 15 ppm, se dice que el agua de la piscina se sometió a un tratamiento de choque. Espere que el nivel de cloro regrese a 1 - 3 ppm antes de encender el PRECAUCIÓN...
  • Page 65: Sección 6. Instrucciones Para El

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Sección 6. Instrucciones para el En las piscinas exteriores, se recomienda mantener un nivel de 50-75 ppm de estabilizador mantenimiento por parte de cloro (ácido cianúrico) en el agua. Esto del usuario resultará...
  • Page 66: Limpieza De La Celda Electrolítica: Según Resulte Necesario

    ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® • Muestra del agua de la piscina. Lleve la muestra • Limpieza con lavado de ácido. Si en la celda de agua a la tienda local de productos para electrolítica tiende a acumularse sarro, se...
  • Page 67: Preparación Para El Invierno

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Si es necesario el procedimiento de lavado con Preparación para el invierno ácido, se recomienda que un representante de Se necesita muy poco cloro en el agua fría. Por debajo servicio de Zodiac analice una muestra del agua de 51 °F (11 °C), el funcionamiento del clorador en...
  • Page 68: Sección 7. Resolución De Problemas

    El nivel de cloro en el agua es muy bajo Aumente el tiempo de filtrado Agregue un estabilizador de cloro (ácido isocianúrico) hasta que llegue a 50-75 ppm Si los problemas continúan, llame al soporte técnico de Jandy al 1.800.822.7933 Página 68...
  • Page 69: Sección 8. Vistas Ampliadas Y

    Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® Sección 8. Vistas ampliadas y kits de reemplazo Página 69...
  • Page 70 ESPAÑOL Clorador de sal comercial Jandy | Manual de instalación y operación ® CÓDIGO DESCRIPCIÓN R0976300 Kit de tornillos R0976400 Sensor de flujo R0976500 Junta del cuerpo principal R0976600 Kit de electrodos JSWC40 R0976700 Kit de electrodos JSWC53 R0976800 Kit de electrodos JSWC80...
  • Page 71 Clorador de sal comercial Jandy | Manual de instalación y operación ESPAÑOL ® NOTAS Página 71...
  • Page 72 Zodiac Pool Systems LLC 2882 Whiptail Loop # 100 Carlsbad, CA 92010, EE. UU. Jandy.com | 1.800.822.7933 Zodiac Pool Systems Canada, Inc. 2-3365 Mainway Burlington, ON L7M 1A6, Canadá Jandy.ca | 1.800.822.7933 ZODIAC ©2022 Zodiac Pool Systems LLC. Todos los derechos reservados.