AIR KIT - FRESH AIR SUPPLY, AIR THROUGH THE BOTTOM
WITH PLINTH.
When the space heater is installed in a structure where direct combustion air is re-
quired, an air kit must be used to supply fresh air ot the appliance from outside.
1. Remove the four M8x30mm
bolts fixing the wood heater to
the plinth.
2. Remove the reflector plate (1)
3. Remove the Knock-Out forms
4. Mount the air box (2)
5. Mount the reflector plate (1)
6. Mount the flex hose (5) to the air
nozzle with the hose clamp (4)
7. Glue the air valve (3) to the plinth
over the hole from the knock-out
form with the gasket (8)
8. Mount the flex hose (5) to the air
valve (3) with the hose clamp (4)
8
1
0005569
2
1
4
5
4
3
8
Scotchmount klebeband 140/100
Knock-out form
Knock-out form
Knock-out form
Knock-out form
59