AIR KIT - FRESH AIR SUPPLY, AIR THROUGH THE BACK
WITH PLINTH.
Scotchmount klebeband 140/100
When the space heater is installed in a structure where direct combustion air is re-
quired, an air kit must be used to supply fresh air ot the appliance from outside.
1. Remove the four M8x30mm
bolts fixing the wood heater to
the plinth.
2. Remove the reflector plate (1)
3. Remove the Knock-Out forms
4. Mount the air box (2)
Knock-out form
5. Mount the reflector plate (1)
6. Mount the flex hose (7) to the air
Knock-out form
nozzle with the hose clamp (4)
7. Mount the air valve on the wall,
over the hole leading to the out
side.
Knock-out form
8. Connect the flex tube to the air
valve using a hose clamp.
Knock-out form