Wiring Diagram - golmar ART 5W/GTWIN User Manual

Hide thumbs Also See for ART 5W/GTWIN:
Table of Contents

Advertisement

ART 5W/GTWIN MONITOR
WIRING DIAGRAMS
A building with 1 column of up to 127 WiFi activated monitors, a 1723/22 transformer connected
to each of the ART 5W monitors and 1 video main panel (push buttons).
MASTER
MONITOR
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
1 ( )
MASTER
MONITOR
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
1 ( )
MASTER
MONITOR
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
1 ( )
MASTER
MONITOR
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
1 ( )
( )
Remove the jumper from all of the
*
distributors except the last.
1 ( )
Configuration of the SAV-GTWIN call
repeater, see p.
37.
( )
2
To connect the FA-Gtwin power supply to
the filter and line protector, see the
TGTWIN SYSTEM MANUAL, p. 44.
( )
3
To connect the secondary AC lock
release (Golmar), see the TGTWIN SYSTEM
MANUAL, p. 45.
( ) 4
Transformer 1723/22 connected to all
ART 5W
master
monitors, allows up to
127 ART 5W monitors with activated
Wifi, see page 32 and 34.
Main panel
Video door
Entry system
( )
3
SE2
ALock release
max. 12 Vdc/270mA.
Please note: Push-button panel up to 122 apartments.
Important:
For further information about the cross-sections distances and o.
diagrams, etc., (see manual "T
LINE IN
LINE OUT
Llamada
CP
Rellano
S+
V+
V~
N~
S-
V-
V~
L~
1723/22 Transformer
( ) 4
LINE IN
LINE OUT
Llamada
CP
Rellano
S+
V+
V~
N~
V-
S-
V~
L~
1723/22 Transformer
( ) 4
LINE IN
LINE OUT
Llamada
CP
Rellano
S+
V+
V~
N~
S-
V-
V~
L~
1723/22 Transformer
( ) 4
LINE IN
LINE OUT
Llamada
CP
Rellano
S+
V+
V~
N~
S-
V-
V~
L~
1723/22 Transformer
( ) 4
LINE
Exterior door
PA
release button
SP
NC
CONTACT
SE+
DOOR CLOSED
SE-
,
GTWIN MANUAL SISTEMA
"). https://doc.golmar.es/search/manual/5012
COL MN
U
D4L-GTWIN
DISTRIBU OR
LINE OUT
LINE
LINE
3
4
( )
Z=ON
*
Llamada
Rellano
N~
L~
1723/22 Transformer
( ) 4
LINE
LINE
1
2
LINE IN
Llamada
Rellano
N~
Mains
Mains
L~
110~230Vac
110~230Vac
1723/22 Transformer
TO THE FOLLOWING DISTRIBUTORS
D4L-GTWIN
LINE OUT
DISTRIBU OR
LINE
LINE
3
4
( )
Z=ON
*
Llamada
Rellano
N~
L~
1723/22 Transformer
( ) 4
LINE
LINE
1
2
LINE IN
Llamada
Rellano
Mains
Mains
N~
L~
110~230Vac
110~230Vac
1723/22 Transformer
( ) 4
=
n
m x.
a of ART 5W
monitors
T
MASTER
MONITOR
LINE IN
LINE OUT
CP
S+
V~
V+
S-
V~
V-
1 ( )
MASTER
MONITOR
LINE IN
LINE OUT
CP
S+
V~
V+
S-
V~
V-
1 ( )
( ) 4
T
MASTER
MONITOR
LINE IN
LINE OUT
CP
S+
V~
V+
S-
V~
V-
1 ( )
MASTER
MONITOR
LINE IN
LINE OUT
CP
S+
V~
V+
S-
V~
V-
1 ( )
L
ocal
( ) 4
(Power supply from
local power supply
JP1
JP2
SW1
No
.1
(
see a e
p g 32)
FA-GTWIN POWER SUPPLY
LINE 1
LINE 2
230
LINE ~
0
see age
p
34.
For the door panel and other wiring
2345
35
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
JP3
INT
F. Line
ON
ON (Z)
1
2
INT 0
power
unit)
O N
=
( )
2

Advertisement

Table of Contents
loading

Table of Contents