*CR800 controller
Notes of the basic component are shown.
CAUTION
Three phase
AC200V
Primary side
Note 1)
Earth
leakage
breaker
(NV)
L1
L2
L3
Secondry side
PE terminal
PE terminal
Note 1) Always use the terminal cover for the earth leakage breaker.
Prepare the following items.
1)
Part name
Earth leakage breaker
Cable for primary power supply
Grounding cable
ACIN cable
2) Confirm that the primary power matches the specifications.
3) Confirm that the primary power is OFF and that the earth leakage breaker power switch is OFF.
4) Connect the ACIN cable to the breaker.
Connect the power terminals of the ACIN cable to the secondary side terminals of the earth leakage breaker.
Also, ground the FG terminal of the cable.
5) Connect the ACIN cable to the ACIN connector on the rear of the controller.
<1> Face the main key on the ACIN cable plug upwards. (Refer to the "ACIN cable connection" illustration.)
<2> Align the main key of the ACIN cable plug with the grooves on the ACIN connector. Push the plug into the
connector as far as it will go.
The plug may be damaged if it is not correctly aligned with the connector.
<3> Tighten the coupling on the ACIN cable, turning it to the right until it locks.
6) Connect one end of the grounding cable to the PE (protective earth) terminal on the controller and ground the
other end (2-point grounding) in order to comply with the requirements of EN 61800-5-1 for the touch cur -
rent of 3.5 mA AC or more.
7) Connect the primary power cable to the primary side terminal of the earth leakage breaker.
Please install the earth leakage breaker in the primary side power supply of the
controller because of leakage protection.
Single phase
AC200V
ACIN cable
(attachment)
L
N
The following is recommended product.
Single phase: NV30FAU-2P-10A-AC100-240V-30mA
(Terminal cover: TCS-05FA2)
Three phase: NV30FAU-3P-10A-AC100-240V-30mA
(Terminal cover: TCS-05FA3)
AWG14 (2mm
AWG14 (2mm
Terminal: M5, cable length: 3m
Controller rear
ACIN connector
PE (protective earth) terminal
M4 screw
Grounding cable
PE terminal
Specifications
2
) or above
2
) or above
ACIN cable connection
Groove for main
<1> <2>
key (wide)
ACIN connector
(female)
Main key (wide)
ACIN cable
(male)
<3>
Coupling
Remarks
Prepared by customer.
Prepared by customer.
Tightening torque for terminal
fixing screw is 2 ~ 3Nm.
Prepared by customer.
Tightening torque for terminal
fixing screw is 2 ~ 3Nm.
Supplied with the product.