Product Certifications - Emerson Rosemount 3144P Quick Start Manual

Temperature transmitter with hart protocol
Hide thumbs Also See for Rosemount 3144P:

Advertisement

April 2015

Product Certifications

European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at www.rosemount.com.
Ordinary Location Certification
As standard, the transmitter has been examined and tested to determine that the
design meets the basic electrical, mechanical, and fire protection requirements
by a nationally recognized test laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
North America
E5 FM Explosionproof, Dust-Ignitionproof, and Nonincendive
Certificate: 3012752
Standards Used: FM Class 3600: 1998, FM Class 3611: 2004, FM Class 3615: 1989, FM
Class 3810: 2005, NEMA-250: 1991, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2009
Markings: XP CL I, DIV 1, GP A, B, C, D; T5(-50 °C ≤ T
G; T5(-50 °C ≤ T
drawing 03144-0320; NI CL I, DIV 2, GP A, B, C, D; T5(-60 °C ≤ T
≤ +50 °C); when installed per Rosemount drawing 03144-0321, 03144-5075;
I5 FM Intrinsic Safety and Nonincendive
Certificate: 3012752
Standards Used: FM Class 3600: 1998, FM Class 3610: 2010, FM Class 3611: 2004, FM
Class 3810: 2005, NEMA-250: 1991, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2009
Markings: IS CL I / II / III, DIV 1, GP A, B, C, D, E, F, G; T4(-60 °C ≤ T
I, Zone 0, AEx ia IIC T4(-60 °C ≤ T
+75 °C); T6(-60 °C ≤ T
03144-5075;
I6 CSA Intrinsic Safety and Division 2
Certificate: 1242650
Standards Used: CAN/CSA C22.2 No. 0-M91 (R2001), CAN/CSA-C22.2 No. 94-M91, CSA
Std C22.2 No. 142-M1987, CAN/CSA-C22.2 No. 157-92, CSA Std C22.2 No. 213-M1987;
Markings:Intrinsically Safe for Class I Groups A, B, C, D; Class II, Groups E, F, G; Class III;
Intrinsically Safe for Class I Zone 0 Group IIC; T4(-50 °C ≤ T
Suitable for Class I, Div. 2, Groups A, B, C, D;
Suitable for Class I Zone 2 Group IIC; T6(-60 °C ≤ T
when installed per Rosemount drawing 03144-5076;
≤ +75 °C); T6(-50 °C ≤ T
a
≤ +60 °C); NI CL I, DIV 2, GP A, B, C, D; T5(-60 °C ≤ T
a
≤ +50 °C); when installed per Rosemount drawing 03144-0321,
a
≤ +85 °C); DIP CL II/III, DIV 1, GP E, F,
a
≤ +60 °C); when installed per Rosemount
a
≤ +60 °C); Type 4X;
a
≤ +60 °C); T5(-60 °C ≤ T
a
Quick Start Guide
≤ +75 °C); T6(-60 °C ≤ T
a
≤ +60 °C); IS [Entity] CL
a
≤ +85 °C);
a
a
a
13