D Iode And Continuity Test - Maxwell Digital Multimeters MX 25 314 User Manual

Digital multimeter inductance measurement
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN
User Manual
dc
voltaGe
Measurement
limit
200 mV
2 V
20 V
200 V
1000 V
• Input resistance: 10 MΩ
• Max input voltage: 1000 V DC
ac
voltaGe
Measurement
limit
200 mV
2 V
20 V
200 V
750 V
• Overvoltage protection: 250 V DC or 250 V AC
RMS value in 200 mV measurement range
• Input impedance: 10 MΩ
• Frequency range: 40 Hz – 1000 Hz,
TRUE RMS display
• Max. input voltage: 750 V AC RMS value
dc
cUrrent
Measurement
limit
200 µA
2 mA
20 mA
200 mA
2 A
10 A
• Overcurrent protection: fuse: F200mA/500V
(6,35mmx32mm) F10A/500V (6,35mmx32mm)
Resolution
Accuracy
0,1 mV
± (0.5% + 3)
0,001 V
0,01 V
± (0.8% + 3)
0,1 V
1 V
± (1.0% + 5)
Resolution
Accuracy
0,1 mV
0,001 V
± (1.0% + 5)
0,01 V
0,1 V
1 V
± (1.2% + 5)
Resolution
Accuracy
0,1 µA
0,001 mA
± (1.0% + 5)
0,01 mA
0.1 mA
0,001 A
± (1.5% + 10)
0,01 A
ac
cUrrent
Measurement
limit
200 µA
2 mA
20 mA
200 mA
2 A
10A
• Overcurrent protection: fuse: F500mA/1000V
(6,35mmx32mm) F10A/1000V
• Frequency range: 40 Hz – 1000 Hz,
TRUE RMS kijelzés
• Max. input voltage: 750 V AC RMS value
r
esistance
Measurement
limit
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
• Overvoltage protection: 250V DC or
250V AC RMS value
d
iode and continUity test
Mode
Diode test
• The display shows the opening
voltage of the diode
Continuity test
• A beeping sound indicates if the
resistance is less than 100Ω
• Overvoltage protection: 250V DC or 250V AC RMS
t
eMperatUre MeasUreMent
Unit
Range
-20°C - 400°C
°c
400°C - 1000°C
-0°F - 752°F
°f
752°F - 1832°F
Resolution
Accuracy
0,1 µA
± (1,2% + 5)
0,001 mA
0,01 mA
± (1,5% + 5)
0.1 mA
0,001 A
± (1,8% + 15)
0,01 A
Resolution
Accuracy
0.1Ω
0,001 kΩ
±(0.8% + 5)
0,01 Ω
0,1 Ω
0,001 MkΩ
±(1,0% + 10)
0,01 MkΩ
±(5,0% + 10)
Resolution
Accuracy
±(2.0 % + 3)
1 °C
±(3.0 % + 3)
1 °F