D Iode And Continuity Test - Maxwell Digital Multimeters MX 25 312 User Manual

Digital multimeter automatic measurement range
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
EN
User Manual
dc
voltaGe
Measurement
limit
60 mV
600 mV
6 V
60 V
600 V
1000 V
• Input resistance: 10 MΩ
• Max input voltage: 1000V DC
ac
voltaGe
Measurement
limit
60mV
600mV
6V
60V
600V
750V
• Overvoltage protection: 250V DC or 250V AC
RMS value in 200mV measurement range
• Frequency range: 40 Hz – 1000 Hz,
TRUE RMS display
• Max. input voltage: 750 V AC RMS value
dc
cUrrent
Measurement
limit
600 µA
6 mA
60 mA
600 mA
6 A
10A
• Overvoltage protection: fuse: F500mA/1000V
(6,35mmx32mm) F10A/500V (6,35mmx32mm)
Resolution
Accuracy
0,01 V
±(0,5% + 5)
0,1 mV
0,001 V
± (0.8% + 3)
0,01 V
0,1 V
1 V
± (1.0% + 5)
Resolution
Accuracy
0,01 mV
± (1.0% + 20)
0,1 mV
± (1.0% + 5)
0,001 V
0,01 V
± (0.8% + 5)
0,1 V
1V
± (1.0% + 5)
Resolution
Accuracy
0,1 µA
± (1.0% + 5)
0,001 mA
0,01 mA
± (0.8% + 5)
0.1 mA
0,001 A
± (1.0% + 10)
0,01 A
ac
cUrrent
Measurement
limit
600 µA
6 mA
60 mA
600 mA
6 A
10A
• Overcurrent protection: fuse: F500mA/1000V
(6,35mmx32mm) F10A/500V
• Frequency range: 40 Hz – 1000 Hz, TRUE RMS
display
• Max. input voltage: 750 V AC RMS value
r
esistance
Measurement
limit
600Ω
6kΩ
60kΩ
600kΩ
6MΩ
60MΩ
• Overvoltage protection: 250V DC or
250V AC RMS value
d
iode and continUity test
Mode
Diode test
• The display shows the opening
voltage of the diode
Continuity test
• A beeping sound indicates if the
resistance is less than 30Ω
• Overvoltage protection: 250V DC or 250V AC RMS
Resolution
Accuracy
0,1 µA
± (1,2% + 5)
0,001 mA
0,01 mA
± (1,5% + 5)
0.1 mA
0,001 A
± (1,8% + 15)
0,01 A
Resolution
Accuracy
0.1Ω
0,001 kΩ
0,01 Ω
±(0.8% + 5)
0,1 Ω
0,001 MkΩ
0,01 MkΩ
±(1.2% + 15)

Advertisement

Table of Contents
loading

Table of Contents