linapter I)-using l Ime I nrougnpur
A NOTE ABOUT LOG RESOLUTION THROUGHPUT
A NOTE ABOUT LOG RESOLUTION THROUGHPUT
Because the log resolution mode measures multiple-decade spans in parallel (see Chapter 2
for details), more records are required when creating a file and setting up a session for log
resolution throughputs, Here are the required number of real time records for each log resolu­
tion span (double these numbers for two-channel throughputs):
Because you do not have to measure in the same mode as you throughput, the number of
records on disc is the same, For example, if you throughput at a 4-decade span, you need to
set a session length of 1000 records,
The number of records required for log resolution throughputs must be taken into considera­
tion twice in this chapter: first when creating the disc file, then again when setting the session
length,
6-4
Span (in decades)
1
2
3
4
5
Number of Records Required
1
1 0
1 00
1000
1 0000