Status Messages And Diagnostic Information - Siemens SITRANS F FX330 Operating Instructions Manual

Vortex flowmeters
Table of Contents

Advertisement

OPERATION
6

6.9 Status messages and diagnostic information

The diagnostic messages are displayed in accordance with NAMUR standard NE 107. The error
messages for the device are divided into status groups, each with one status signal. There are 16
status groups with fixed status signals and 8 groups with variable status signals. To facilitate
identification of the problem source, the status groups are then divided into: Sensor, Electronics,
Configuration and Process.
INFORMATION!
As a status message, always the event group name and the the status signal (F/S/M/C) are
displayed.
Each status message (= status signal) has a specific symbol, determined by NAMUR, which is
displayed with the message. The length of each message is limited to one line.
Symbol
Letter
F F F F
S
M
C
I
Table 6-36: Symbols for status messages
INFORMATION!
Some of the following elimination measures require a hard reset. In case a hard reset is
performed please wait for approx. 10 seconds before powering the device again.
90
Status signal
Failure
Out of specification
Maintenance required
Function check
Information
www.siemens.com/flow
Description and consequence
No measurement possible.
Measurements are available but are no
longer sufficiently accurate and should be
checked.
Measurements are still accurate but this
could soon change.
A test function is active. The displayed or
transferred measured value does not
correspond to the actual measured value.
No direct influence on the measurements.