OPERATION
6
Function
C6 Device
C6.2.1 Login
C6.2.2 Change Password
C6.2.3 Reset Passwords
C6.2.4 Unlock SIL
C6.3 Extras
C6.3.1 Meter Type
C6.3.2 Heat
C6.3.3 Heat & Dens. by Pres.
C6.3.4 Heat & Dens. & FAD
C6.4 Errors
C6.4.1 Message View
C6.4.4 Error Mapping
C6.4.4.1 Totalizer
Table 6-31: Menu description C6.1 - C6.4
Function
C6 Device
C6.5 Units
6.5.1 Volume Flow
6.5.3 Norm. Vol. Flow
6.5.5 Mass Flow
6.5.7 Power
6.5.9 Volume
6.5.11 Norm. Volume
6.5.13 Mass
6.5.15 Energy
6.5.17 Pressure
6.5.19 Temperature
6.5.21 Density
C6.6 Factory Default
C6.6.1 Reset to Fact. Def.?
C6.8 Proof Test
Table 6-32: Menu description C6.5 - C6.8
86
Setting / Description
Enter four digit password to gain a specific access level (for details refer to
and permissions
on page 58).
Change the password associated to the access level currently active.
Reset all passwords to their default setting (for details refer to
permissions
on page 58).
Enter four digit password to unlock SIL mode (if not unlocked by order) and confirm
with enter key. For details refer to "Safety Manual".
Display of meter type as activated in A10 or C6.3.2...C6.3.4 (read-only).
Activate a different meter type in order to enable advanced measurement options
(Gross/net heat, density by pressure or FAD) using a unique authorisation code.
Contact manufacturer to obtain this code.
NAMUR messages (F, S, M, C, I)
For further information refer to
90.
For specific NE 107 events it is possible to redefine the status type.
This function defines the NE 107 status type for the totalizer overflow.
Select: Information / Maintenance Request / Out of Specification / Function Check /
Failure / None
Setting / Description
C6.5.2 Cst. Volume Flow
In all even numbered menus C6.5.2 to .22 Cst. Units (Custom Units) there is a submenu
with the prompt for "Text", "Offset" and "Factor".
6.5.4 Cst. Norm. Vol. Flow
6.5.6 Cst. Mass Flow
6.5.8 Cst. Power
6.5.10 Cst. Volume
6.5.12 Cst. Norm. Volume
6.5.14 Cst. Mass
6.5.16 Cst. Energy
6.5.18 Cst. Pressure
6.5.20 Cst. Temperature
6.5.22 Cst. Density
Query: Reset to Fact. Def.?
Press "→" and confirm reset to factory default with "Yes" or refuse with "No".
For details refer to the "Safety Manual".