Siemens SITRANS F FX330 Operating Instructions Manual page 83

Vortex flowmeters
Table of Contents

Advertisement

SITRANS FX330
Function
C3 Communication
C3.1.2.3 Long Tag
C3.1.2.4 Manufacturer ID
C3.1.2.5 Device Type
C3.1.2.6 Device ID
C3.1.2.7 Universal Revision
C3.1.2.8 Device Revision
C3.1.2.9 Software Revision
C3.1.2.10 Hardware Revision
C3.1.3 Device Information
C3.1.3.1 Descriptor
C3.1.3.2 Message
C3.1.3.3 Date
C3.1.3.4 Cfg. Change Counter
C3.1.4 HART Variables
C3.1.4.1 Current Out. Meas.
C3.1.4.2 Frequency Out.
Meas.
C3.1.4.3 Current Input Meas.
C3.1.4.4 Quaternary HART
C3.1.5 Catch DV Temp.
C3.1.5.1 Capture Mode
C3.1.5.2 Exp. Device Type
C3.1.5.3 Slave Device ID
C3.1.5.4 Capture Command
C3.1.5.5 Slot Number
C3.1.5.6 Shed Time
C3.1.6 Catch DV Pressure
Table 6-28: Menu description C3
05/2019 - A5E36751269-AE
Setting / Description
Enter long measuring point identifier (1...32 digits).
Entry will be displayed in the header bar on the LC display (depending on letter size,
min. 11 digits can be displayed).
®
HART
Manufacturer ID = 00042 (0x2A) [SIEMENS] (read-only)
Device Type = 00058 (0x3A) (read-only)
Individual device ID (read-only)
®
HART
revision (read-only)
(read-only)
(read-only)
(read-only)
Informative text can be added to describe the device in the HART
Commenting text to label instrument can be added; 1...16 digits.
Here additional information can be added.
Customer-defined date can be set here.
Counter for changes in settings (read-only).
®
Definition of HART
variables.
®
Primary HART
variable; identical with current output measurement variable.
®
Secondary HART
variable; identical with frequency output measurement variable. If
binary output is not activated or not configured as frequency output, the secondary
®
HART
variable is selectable. The variable selection is depending on the device
configuration.
®
Tertiary HART
variable; identical with current input measurement variable. If the
current input is not activated, the secondary HART
selection is depending on the device configuration.
Select (Availibility depending on fluid and medium configuration): Volume Flow / Norm.
Volume Flow / Mass Flow / Gross Power / Net Power / FAD / Volume / Norm. Volume /
Gross Energy / Net Energy / Density / Temperature1 / Temperature2 / Pressure /
Vortex Frequency / Velocity / Specific Enthalpy / Specific Heat Capacity / Reynolds
Number
Catch device variable allows for capturing process data from another field device in a
multidrop network.
ACK - listen to responses by a specific slave device
BACK - listen to bursts by a specific slave device
OFF - disable capture mode
Define expanded device type for source slave.
Enter: 000...65535
Enter source slave address
Select source command number: 1 / 2 / 3 / 9 / 33
Describes slot to process in response message. Select 1...8 (depending on source
command number).
Shed time for mapping.
Define: 0...max.
Same options as C3.1.5.
www.siemens.com/flow
OPERATION
®
communication loop.
®
variable is selectable. The variable
6
83