Table 33. Fan population rule for HS5620 with Open Server Manager (OSM) (continued)
configuration
No backplane
Optional HW
Rear Module
Not supported
BOSS N1
Fan 1 with HPR
Gold fan
Fan 2 to Fan 6
with STD fan
GPU
Fan 1 with HPR
Gold fan
Fan 2 to Fan 6
with HPR Silver
fan
Thermal restrictions for PCIe adapter card and others with Open Server Manager
(OSM)
● Cannot support PCIe adapter with the cooling requirement more than 200 LFM at 55C in 3.5-inch drives configuration.
● Cannot support PCIe adapter with the cooling requirement more than 300 LFM at 55C in 2.5-inch drives configuration.
● Cannot support OCP card with the cooling requirement more than 250 LFM at 55C in 2.5-inch drives configuration.
● Only support the optical transceiver with higher temperature spec (≥ 85°C) (M14MK / N8TDR).
● Rear PERC adapter with BBU is not supported in 12 x 3.5-inch drive configuration.
Thermal Restrictions for PCIe adapter NIC and other network cards
● Cannot support PCIe card with the cooling requirement more than 300LFM at 55C in 12 x 3.5-inch SAS/SATA configuration.
● Solarflare Melrose DP 25 GBE SFP28 (TTKWY) not supported with 12 x 3.5-inch SAS/SATA configuration.
● 100 Gb network adapter or 100 Gb OCP is not supported in 12 x 3.5-inch SAS/SATA configuration.
● Few 25 GB OCP cards with the cooling requirement more than 250LFM at 55C (3Y64D / 4TRD3 / GGGDF / R1KTR /
Y4VV5) is not supported in 12x3.5" SAS/SATA configuration.
● 12 x 3.5-inch SAS/SATA configuration requires the optical transceiver with higher temperature spec (≥ 85°C) to support
(M14MK / N8TDR).
● Quad port OCP (3Y64D/Y4VV5) requires the optical transceiver with higher temperature spec (≥ 85°C) to support
(M14MK).
● 100 Gb network adapter can't support the transceivers as 14NV5 / 9JKK2 / QSFP56 (MFS1S00-VxxxE / HxxxE).
Thermal restrictions for extended ambient support (ASHRAE A3/A4)
● Two PSUs are required in redundant mode. Single PSU failure is not supported.
● 12 x 3.5-inch SAS/SATA configuration is not supported.
● BOSS(M.2) module is not supported.
8 x 3.5-inch
12 x 3.5-inch
SAS
SAS
Fan 2 to Fan 6
with HPR Silver
fan
Not supported
Fan 1 with HPR
Gold fan
Fan 2 to Fan 6
with HPR Silver
fan
Fan 1 with HPR
Fan 1 with HPR
Gold fan
Gold fan
Fan 2 to Fan 6
Fan 2 to Fan 6
with STD fan
with HPR Silver
fan
Not supported
Fan 1 with HPR
Gold fan
Fan 2 to Fan 6
with HPR Silver
fan
8 x 2.5-inch
8 x 2.5-inch
SAS
NVMe
Not supported
Not supported
Fan 1 with HPR
Fan 1 with HPR
Gold fan
Gold fan
Fan 2 to Fan 6
Fan 2 to Fan 6
with STD fan
with HPR Silver
fan
Fan 1 with HPR
Fan 1 with HPR
Gold fan
Gold fan
Fan 2 to Fan 6
Fan 2 to Fan 6
with HPR Silver
with HPR Silver
fan
fan
Technical specifications
24 x 2.5-inch (16
x 2.5-inch + 8 x
2.5-inch NVMe)
Not supported
Fan 1 with HPR
Gold fan
Fan 2 to Fan 6
with HPR Silver
fan
Not supported