Dell PowerEdge HS5620 Installation And Service Manual page 100

Table of Contents

Advertisement

Table 70. Cable routing - 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe drive backplane configuration with
rear mounted fPERC (PERC11), riser 1C with dual processor configuration
From
CTRL_SRC_SB1 (signal connector on PERC)
BP_PWR_1 (power connector on the backplane)
CTRL_DST_PA1 (signal connector on PERC)
FAN_SIG (signal connector on fan board)
CTRL_DST_PB1 (signal connector on PERC)
BP_DST_PA1 (signal connector on backplane)
BP_DST_PB1 (signal connector on backplane)
BP_DST_PA2 (signal connector on backplane)
BP_PWR_1 ((power connector on backplane)
BP_DST_PB2 (signal connector on backplane)
SYS_PWR_0 (power connector on system board)
SL9_CPU2_PB5 (signal connector on system board)
SL10_CPU2_PA5 (signal connector on system board)
SL11_CPU1_PA6 (signal connector on system board)
SL12_CPU1_PB6 (signal connector on system board)
Figure 61. Cabling diagram of configuration 2 - 12 x 3.5-inch + 2 x 2.5-inch SAS/SATA backplane and rear drive
module with single, and dual processor configuration (PERC11)
Table 71. Cable routing - 12 x 3.5-inch + 2 x 2.5-inch SAS/SATA backplane and rear drive module with
single, and dual processor configuration (PERC11)
From
BP_DST_SA1 (signal connector on backplane)
BP_PWR_1 (power connector on backplane)
BP_DST_SB1 (signal connector on backplane)
100
Installing and removing system components
To
BP_DST_SB1 (signal connector on backplane)
SIG_PWR_1 (power connector on the PIB)
SL5_CPU1_PA3 (signal connector on system board)
FAN_SIG_1, FAN_SIG_2 (fan signal cable on system board)
SL6_CPU1_PB3 (signal connector on system board)
SL8_CPU1_PA4 (signal connector on system board)
SL7_CPU1_PB4 (signal connector on system board)
SL1_CPU2_PA1 (signal connector on system board)
SIG_PWR_3 (power connector on PIB)
SL2_CPU2_PB1 (signal connector on system board)
Power connector soldered on riser
Signal connector soldered on riser
Signal connector soldered on riser
Signal connector soldered on riser
Signal connector soldered on riser
To
CTRL_SRC_SA1 (signal connector on PERC adapter)
SIG_PWR_1 (power connector on PIB)
CTRL_SRC_SB1 (signal connector on PERC adapter)

Advertisement

Table of Contents
loading

This manual is also suitable for:

E88s

Table of Contents