Daikin RXM20R Service Manual page 97

Hide thumbs Also See for RXM20R:
Table of Contents

Advertisement

Repair procedures
To remove the DC fan motor assembly
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
DC fan motor measurements are
correct?
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Click the indoor unit fan motor cover out of the indoor unit. If needed, remove
the screw (if installed) on the right hand side of the fan motor cover for easier
removal.
A
A Class 20~42 unit
a Indoor unit fan motor cover
A
A Class 50~71 unit
a Indoor unit fan motor cover
3 Remove the rubber from the indoor unit.
Action
Replace the DC fan motor, see
4
procedures" [
"4.14 Plate
4
"4.14 Plate
work" [
 153].
a
a
4
Components
|
"Repair
 97].
4
work" [
 153].
Service manual
97