4
|
Components
Service manual
70
A
a
A Class 20~35 unit
a Compressor pipe
A
a
A Class 42~71 unit
a Compressor pipe
CAUTION
Overheating the compressor pipes (and the oil inside the compressor pipes) will
damage or destroy the compressor.
9 After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
10 Install the putty on the compressor accumulator.
11 Install the compressor thermal protector, see
4
thermal
protector" [
12 Connect the Faston connectors to the compressor wire terminals U, V and W
 76].
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
a
a
"To install the compressor
FVXM25~50A
Split New Perfera R32