2 Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
3 Unhook the tab(s) on the bottom and remove the electrical wiring box cover.
a Screw
b Protruding part on the top of the cover
c Tab
Floor standing units
TO OPEN THE TERMINAL BLOCK
1 Remove the front grille.
2 Remove 1 lower screw.
3 Lift the sensor securing plate.
4 Move the metal plate cover down and then towards you to remove it.
a
b
c
a Screw
b Sensor securing plate
c Metal plate cover
TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite: Open the terminal block.
1 Remove 1 screw from the electrical wiring box.
2 Unhook the 2 tabs on the electrical wiring box cover and remove it.
a
b
c
c
b
1
3
c
2
4