9 Release the 2 hooks and remove the piping fixture.
10 Release the flared joint of the (refrigerant) liquid pipe and the gas pipe.
Disconnect the liquid and gas pipes from the refrigerant field piping. Plug the
refrigerant field pipes to prevent dirt from entering the pipes.
11 Remove the screw and disconnect the ground wire from the indoor unit heat
exchanger.
12 Unfasten the 2 hooks on the left side of the indoor heat exchanger.
a
a
a Hook (left side)
b Hook (right side)
c Indoor unit heat exchanger
13 Unfasten the 2 hooks on the right side of the indoor heat exchanger and
remove the indoor unit heat exchanger.
14 Remove the 4 screws and remove the bellmouth from the indoor unit.
a
b
a
a Screw (bellmouth)
b Bellmouth
c Nut (turbo fan assy)
d Turbo fan assy
15 Remove the nut that fixes the turbo fan assembly.
16 Pull and remove the turbo fan assembly from the DC fan motor assembly.
INFORMATION
Use a pulley remover if the propeller cannot be removed manually.