1 Connect the wiring harness to the swing flap motor.
2 Install the swing flap motor on the correct location on the indoor unit. Make
sure the swing flap motor shaft is correctly inserted in the link.
a
b
a Main swing flap
b Secondary swing flap
c Screw (swing flap motor fixation)
d Swing flap motor
3 Install and tighten the screw to fix the swing flap motor.
4 Install the secondary swing flap in the indoor unit (by clicking it on).
5 Install the main swing flap in the indoor unit (by clicking it on).
6 Install the switch box, see
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the swing flap motor, see
INFORMATION
The swing flap motor wiring harness is also connected to the swing raster motor.
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
c
d
4
"4.14 Plate
work" [
 153].
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"4.14 Plate
"Repair
procedures" [
4
Components
|
4
work" [
 153].
4
 178].
Service manual
179

Advertisement

Table of Contents
loading

Table of Contents