RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
7 Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
c
d
a Screw (swing raster motor assembly)
b Swing raster motor assembly
c Fan guard
d Swing raster motor rod
8 Connect the swing raster motor rod to the swing raster shaft using soft tools.
9 Tighten the 2 screws to properly fix the swing raster motor assembly.
10 Install the fan guard.
11 Connect the drain hose to the indoor unit.
a Screw (drain hose)
b Drain hose
12 Install the drain hose fixation bracket. Install and tighten the screw.
13 Install the switch box, see
Is the problem solved?
Yes
No
a
b
a
b
a
"4.14 Plate
work" [
4
 153].
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.