Daikin RXM20R Service Manual page 131

Hide thumbs Also See for RXM20R:
Table of Contents

Advertisement

RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
c b a
d
e
a U
b V
c W
d DC+
e DC–
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
VDC
Com
U
DC+
V
DC+
W
DC+
DC–
U
DC–
V
DC–
W
Power module IPM2 for fan motor
1 Disconnect the fan motor connector from the main PCB.
2 Check the power module IPM2 in reference with the image and the table
below.
Ref
VDC
0.501 V
DC+
0.501 V
DC+
0.501 V
DC+
0.501 V
U
0.501 V
V
0.501 V
W
4
Components
|
Com
Ref
U
O.L
V
O.L
W
O.L
DC–
O.L
DC–
O.L
DC–
O.L
Service manual
131