PREVENTIVE MAINTENANCE (TO BE PERFORMED BY TRAINED SERVICE PROVIDER) - Page 2 of 2
WARNING! TURN OFF CASE BEFORE PERFORMING PREVENTIVE MAINTENANCE!
Preventive
Frequency
Maintenance
Case Exterior
Quarterly Compressor Area: Disconnect power from case before cleaning
Quarterly Hot Gas Condensate Pan: Use a de-scaling solution (such as CLR®)
Quarterly Under Case Cleaning: Once condenser package is clear of unit, vacuum
Case Interior
Quarterly Tub, Coil, Drain, Fan Blades, Motors, Brackets:
Quarterly Honeycomb: See MAINTENANCE FUNDAMENTALS: HONEYCOMB
condenser coil!
Slide/Roll out from under case.
Use moist cloth to wipe off dust & debris that collects on various parts.
that will prevent corrosion, lime and rust, to clean pan. Use spray bottle to
evenly spread solution throughout. Rinse thoroughly with spray bottle filled
with clean water and sponge.
under case to remove all dust and dirt that may collect under case.
Caution! Disconnect power from the case before cleaning the Tub, Coil,
Fan, Motor and Drain Area!
Remove Decking, Sub-Deck and Fan Shroud.
Use vacuum to clean Evaporator Coils.
Clean Tub, Coil and Drain with warm water, clean cloth, brush and
mild soap solution.
Remove any debris that may clog drain.
Clean Fan Blades, Motors and Brackets by wiping down with moist
cloth.
AIR DIFFUSERS section in this manual for cleaning specifics.