CLEANING SCHEDULE (PERFORMED BY STORE PERSONNEL & TRAINED SERVICE PROVIDERS)
Cleaning
D*
Clean Case
X
Exterior
Clean Case
X
Interior
Clean
Condensing
Coil
Magnetic
Condenser
Coil Filter
Evaporator
Fan Shroud
Area (Trained
Svc. Providers
Only)
Tub & Drain
(Trained
Service
Providers
Only)
*D = Daily / *W = Weekly / *M = Monthly / *Q = Quarterly
W* M*
Q*
Acrylic must be cleaned with a mild soap and water solution and a
soft cloth (Never use a household cleaner on acrylic).
Shelves and decks can be cleaned with a warm soap and water
solution.
X
Remove decks. Clean with soap and water.
Vacuum tub under deck. Clean with soap and water. Wipe dry with
X
clean cloth.
Keep drains clean and free of debris which could clog the drain and
X
rob the case of needed refrigeration.
Clean the condenser coil. Using air pressure if available, or an
X
industrial strength vacuum, clean the dust and dirt that collects on
condenser coil. Be careful not to damage the fins on the coil.
Magnetic Condenser Coil Filter (Self-Contained Units Only):
•
This filter prevent dust particles from entering condenser coil.
•
It is accessible at case rear.
•
Clean magnetic condenser coil filter by following either step 1 or
2; then follow step 3:
1. Magnetic condenser coil filter is dishwasher safe. Remove
from case (no screw removal required) and use a rag or
soft-bristled brush to wipe off excess dust particles from filter.
Run in normal dishwasher cycle. Remove from dishwasher.
X
Dry with soft cloth / paper towel. Return to case.
2. If not using dishwasher, remove magnetic condenser coil filter
from case. Use a rag or soft-bristled brush to wipe off excess
dust particles from filter. Submerse in warm, soapy water.
Use soft-bristled brush to remove dust, dirt, grease and grime
that collects on filter. Rinse thoroughly.
3. Dry with soft cloth or paper towel or allow to air dry. Replace.
Evaporator Fan Shroud Area (Under Decking): Caution! Due to
rotating fans in area, turn off case and disconnect plug from wall
X
outlet before beginning fan shroud / tub area cleaning! 1) Turn off
power. 2) Remove decks from case. 3) Clean fan shroud area (and
surrounding tub area) with moist cloth.
Tub & Drain: Caution! Due to rotating fans, turn off case. Disconnect
plug from wall outlet before beginning tub & drain cleaning! Vacuum
X
tub under decks. Clean with soap and water solution. Wipe dry with
clean cloth. Keep drain free of debris to prevent clogging.
Task
21
Need help?
Do you have a question about the HECO37R and is the answer not in the manual?