ELECTRICAL REQUIREMENTS
Voltage-
Amperage
Model
Hertz-
Draw
Breaker Size
Wire Size
Phase
(Amperage)
MFS25
208-240/60/3
4.3
15
12
MFS35
208-240/60/3
7.8
15
12
MFS50
208-240/60/3
14
20
12
MFS75/80
208-240/60/3
14
20
12
MFS90/100
208-240/60/3
25
30
10
MFS125
208-240/60/3
30
40
8
NOTE:
1. All figures are approximate and are subject to change. For more information see lnstal-
lation Manual that comes with the product.
2. Wire size is based on runs of 50 feet or less (*).
3. Individual branch circuits servicing only one washer is recommended.
4. Washer must be grounded in accordance to National Electric Codes and local codes
ordinances.
5. Three phase hookups require four wires. (3 wires plus ground).
* Do not attempt to use a smaller wire size than specified, even though the wire size may
have a current carrying capacity greater than the required circuit breaker. When making
electrical connections, use the wire size indicated in the chart when runs are up to 50
feet. Use the next larger size for runs 50 to 100 feet from circuit panel to washer.
MOTOR HORSEPOWER (KW)
Model
MFS25
MFS35
MFS50
MFS75/80
MFS90/100
MFS125
16009607
Wash Motor HP {KW)
Extract Motor HP (KW)
Wash
Distribution
Low
High
.18 (.13)
.6 (.45)
1 (.75)
1.3 (1.0)
.4 (.3)
.4 (.3)
1.7 (1.3),
1.7 (1.3)
.7 (.55)
.9 (.65)
2.4 (1.8)
3 (2.2)
1 (.75)
1.2 (.9)
3 (2.2)
3.5 (2.6)
1.3 (1.0)
1.5 (1.1)
6 (4.5)
7.8 (5.8)
1.6(1.2)
1.9(1.4)
6.7 (5)
8.7 (6.5)
Section 5. Specifications & Wiring Schematics
©1999 Maytag Appliances Sales Company
5-2