Configuring The Dip Switches - Banner DX80G9M2S-P7 Manual

Surecross performance flexpower gateway
Hide thumbs Also See for DX80G9M2S-P7:
Table of Contents

Advertisement

SureCross Performance FlexPower Gateway
6. Conduct a site survey between the Gateway and Nodes. If the site survey instructions are not included in this datasheet, refer to the
product manual for detailed site survey instructions.
7. Install your wireless sensor network components. If installation instructions are not included in this datasheet, refer to the product
manual for detailed installation instructions.
For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso-
ries, refer to one of the following product manuals.
• SureCross Quick Start Guide: Banner part number
• SureCross Wireless I/O Network Manual:
• Web Configurator Manual (used with "Pro" and DX83 models):
• Host Configuration Manual

Configuring the DIP Switches

Before making any changes to the DIP switch positions, disconnect the power. For devices with batteries integrated into the housing,
remove the battery for at least one minute. DIP switch changes will not be recognized if power isn't cycled to the device.
For parameters not set via DIP switches, use the User Configuration Tool (UCT) to make configuration changes. For parameters set
using the DIP switches, the DIP switch positions override any changes made using the User Configuration Tool.
Accessing the Internal DIP Switches
To access the internal DIP switches, follow these steps:
1. Unscrew the four screws that mount the cover to the bottom housing.
2. Remove the cover from the housing without damaging the ribbon cable or the pins the cable plugs into.
3. Gently unplug the ribbon cable from the board mounted into the bottom housing. For integrated battery models (no ribbon cable) and
Class I, Division 2 certified devices (ribbon cable is glued down), skip this step.
4. Remove the black cover plate from the bottom of the device's cover.
The DIP switches are located behind the rotary dials.
After making the necessary changes to the DIP switches, place the black cover plate back into position and
gently push into place. Plug the ribbon cable in after verifying that the blocked hole lines up with the missing
pin. Mount the cover back onto the housing.
DIP Switch Settings
Device Settings
Transmit power level: 1 Watt (30 dBm)
Transmit power level: 250 mW (24 dBm), DX80
compatibility mode
Modbus or UCT configured (overrides switches
5-8)
DIP switch configured (Uses 5-8 for I/O configura-
tion)
12 inputs, 0 outputs
11 inputs, 1 output
10 inputs, 2 outputs
9 inputs, 3 outputs
8 inputs, 4 outputs
P/N 155285_web
Rev. D
128185
132607
132114
1
OFF*
ON
www.bannerengineering.com - tel: 763-544-3164
134421
Switches
2
3
4
OFF*
ON
5
6
7
OFF*
OFF*
OFF*
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
8
OFF*
ON
OFF
ON
OFF
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx80g2m2s-p7

Table of Contents