6 | Compressor assembly

INFO
6.1 Storage and transport
?
6.2 Setting up
ATTENTION Attachments (e.g. pipe holders, additional units, fastening parts,
3
2
© Danfoss | Climate Solutions | 2023.06
New compressors are factory-filled with inert gas. Leave this ser-
vice charge in the compressor for as long as possible and prevent
the ingress of air. Check the compressor for transport damage
before starting any work.
Storage at (-30°C) - (+70°C), maximum permissible relative humidity
10% - 95%, no condensation
Do not store in a corrosive, dusty, vaporous atmosphere or in a com-
bustible environment.
Use transport eyelet.
Do not lift manually!
Use lifting gear!
etc.) directly to the compressor are not permissible!
Provide adequate clearance for maintenance work.
1
Ensure adequate compressor ventilation.
Do not use in a corrosive, dusty, damp atmosphere or a
combustible environment.
Setup on an even surface or frame with sufficient load-
bearing capacity.
Single compressor preferably on vibration damper.
Duplex and parallel circuits always rigid.
Sun protection: If the compressor is set up outdoors, it has
to be protected from direct sunlight.
F
E
D